期刊文献+

并行共焦测量中的并行光源技术综述 被引量:10

Survey of parallel light source technology in parallel confocal measurement
下载PDF
导出
摘要 并行共焦测量技术的核心是将单点共焦测量变成多点同时扫描测量,从而使共焦测量速度显著提高。本文介绍了共焦测量技术原理,综述了用于并行共焦的并行光源技术,分析了这些方法的优点和不足。结合作者近年来的研究成果,重点阐述了基于微透镜阵列和数字微镜器件(DMD)产生并行光源的新方法。分析和研究了DMD的空间光调制机理,最终建立了一种单光源双光路并行像散共焦测量系统。 Parallel confocal measurement technology changes traditional simple scanning into a multi-spot scanning, and it will improve the efficiency of measurement significantly. In this paper, the working principle of confocal measurement technology is introduced and some methods to produce a parallel light source in the parallel eonfoeal measurement are surveyed. Then, it analyzes the advantages and disadvantages of these methods. At last, it presents the latest research achievements, and describes new methods to produce the par-allel light source based on the micro lens array and the Digital Micro-lens Device (DMD). By analysis of the mechanism of spatial light modulation, it establishes a laser parallel astigmatism measuring system based on a parallel light source and dual beam paths.
出处 《中国光学》 EI CAS 2013年第5期652-659,共8页 Chinese Optics
基金 国家自然科学基金资助项目(No.50775063) 教育部新世纪优秀人才支持计划资助项目(No.NCET-10-0116) 华侨大学高层次人才科研启动费资助项目(No.12BS109)
关键词 共焦显微镜 并行光源 并行共焦测量 三维形貌术 微透镜阵列 数字微镜器件 confocal microscopy parallel light source parallel confocal measurement 3-D topography micro-lens array Digital Micro-lens Device (DMD)
  • 相关文献

参考文献8

二级参考文献69

共引文献116

同被引文献97

  • 1王忠立,赵清洁.高动态图像获取技术[J].光学技术,2006,32(z1):279-282. 被引量:12
  • 2RUCKSTUHL T, WALSER A, VERDES D, et al. Confocal reader for biochip screening and fluorescence microscopy[J]. Biosensors and Bioelectronics, 2005, 20(9): 1872-1877.
  • 3ZHAO W Q, SUN R D, QIU L R, et al. Laser differential confocal radius measurement [J]. Optics Express, 2010, 18(3): 2345-2360.
  • 4ZHAO W Q, JIANG Q, QIU L R, et al. Dual-axes differential confocal microscopy with high axial resolution and long working distance [J]. Optics Communications, 2011, 284(1): 15-19.
  • 5GRANT D M, McGINTY J, McGHEE E J, et al. High speed optically sectioned fluorescence lifetime imaging permits study of live cell signaling events [J]. Opt. Express, 2007, 15(24): 15656-15673.
  • 6SHI Y, WANG L Q. Fast confocal endomicroscopy based on multi-fiber parallel scanning [J]. SPIE, 2010, 7845: 78451C.
  • 7ROBERTSON M A,BORMAN S,STEVENSON R L. Estimation-theoretic approach to dynamic range enhancement using multiple exposures[J]. J. Electron. Imaging,2003,12(2):219-228.
  • 8GOSHTASBY A A. Fusion of multi-exposure images[J]. Image and Vision Computing,2005,23(6):611-618.
  • 9SZELISKI R. System and process for improving the uniformity of the exposure and tone of a digital image:US,6687400, 2004-02-03.
  • 10SHENG B,NING X,KING W C L,et al.. Design and Implementation for image Reconstruction of Compressive Sensing Using FPGA [C]. Proceedings of the 2013 IEEE International Conference on Cyber Technology in Automation,Control and Intelligent Systems.Nanjing,China,2013:320-325.

引证文献10

二级引证文献45

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部