期刊文献+

纸张中荧光增白剂迁移规律 被引量:7

Migration Rules of Fluorescent Whitening Agent in Paper
原文传递
导出
摘要 建立以水为提取剂,采用紫外分光光度法测定纸张中荧光增白剂迁移量的方法。该方法提取温度40℃,提取时间2 h,提取剂用量40 mL·g^(-1)。定量标准曲线为y=38.31x+0.264(R^2=0.9996),当浓度在0~30μg·mL^(-1)范围内时,浓度和吸光度有很好的线性关系,方法检出限0.04μg·g^(-1),回收率为85%~90%,6次平行测量相对标准偏差RSD小于3%,表明该方法准确可靠,可用于纸张中荧光增白剂迁移量的测定。 UV-Spectrophotometry Quantitative method for determining fluorescent whitening agent (FWAs) in paper with water for extraction agent was studied. On the condition of extraction temperature time was 40℃ and time was 2hs the extraction amount was 40 mL water per 1 gram paper. If the concentrations of FWAs were from 0 to 30 μg·mL^-1, they had a linear relationship with absorbance. Moreover, the calibration curve was y=38.31x+0.264, and R2=0.9996, the limits of detections is 0.04μg·g ^-1, the average recovery was from 85% to 90%, RSD of six results were less than 3%. These results showed the method has high precision and reliability and can be used to determine migration amount of fluorescent whitening agent in paper.
作者 范建云 王鹏
出处 《纸和造纸》 北大核心 2013年第10期27-29,共3页 Paper and Paper Making
基金 湖北省教育厅青年人才项目(Q20131402)
关键词 纸张 荧光增白剂 紫外分光光度计 迁移 paper fluorescent whitening agents UV-spectrophotometry migration