期刊文献+

架空输电线路导线弧垂在线监测误差分析及方法比较 被引量:30

Error Comparison Among Three On-line Monitoring Methods of Conductor Sag of Overhead Transmission Line
下载PDF
导出
摘要 架空输电线路的导线弧垂是反映线路安全运行的重要参数,也是输电线路在线监测和动态增容需要重点关注的状态量之一。为了实时掌握输电线路的运行状态,国内外非常重视导线弧垂的在线监测,也形成了几种比较成熟的监测方法。笔者立足于国内外实际应用情况,重点对导线温度、张力以及倾角传感器监测弧垂的测量精度在理论上和应用上进行了分析和比较研究。在传感器精度足够高的前提下,研究结果表明3种方法监测弧垂的误差都在4%以内,其中张力传感器法误差最小达1%,3种方法都能满足工程要求。 Conductor sag of a transmission line is an important parameter for evaluating the safety of the transmission line, and it is also one of the key parameters in on-line monitoring and dynamic expansion of capacity of the transmission line. For real-time control of transmission line's operation, on-line monitoring of conductor sag has attracted great attention in the world, consequently, several mature monitoring methods have been presented. According to the applications, the authors analyze and compare three on-line monitoring methods of conductor sag in terms of their monitoring accuracy. Three methods use conductor temperature sensor, tension sensor, and tilt angle sensor, respectively, to monitor the conductor sag. The results show that if the accuracy of the sensors is high enough, three methods can all meet the requirement of engineering with the errors below 4%, of which the monitoring method with tension sensor gets the smallest error of 1%.
出处 《高压电器》 CAS CSCD 北大核心 2014年第4期27-34,共8页 High Voltage Apparatus
基金 国家自然科学基金项目(50977057) 国家科技部国际合作项目(2013DFG71630)~~
关键词 输电线路 弧垂 在线监测 导线温度 张力 倾角 transmission line sag on-line monitoring conductor temperature tension tilt angle
  • 相关文献

参考文献21

  • 1窦小晶,瑚跃进,陈贵锋,杜强.750 kV凉乾线路弧垂测量及其误差分析[J].电网与清洁能源,2009,25(5):15-18. 被引量:7
  • 2SEPPA T O. A practical approach for increasing the ther- mal capabilities of transmission lines[J]. IEEE Transac- tions on Power Delivery, 1993, 8(3): 1536-1550.
  • 3SEPPA T O. Accurate ampacity determination:tempera- ture-sag model for operational real time ratings [J]. IEEE Transactions on Power Delivery, 1995, 10(3): 1460-1470.
  • 4SEPPA T O. Use of on-line tension monitoring systems for real time ratings, ice loads and other environmental effects IcY CIGRE . Paris,France :IEEE, 1998:22-102.
  • 5任丽佳,盛戈嗥,李力学,曾奕,江秀臣.动态确定输电线路输送容量[J].电力系统自动化,2006,30(17):45-49. 被引量:49
  • 6Company Usi-power. Power donut 2^TM system for overhead transmission line monitoring[EB/OL], http://www.usi-power. com/Products%20 & %20Services/Donut/Power Donut2_Qu- alifications.pdf.October 2006,2006-10-13.
  • 7周海滨,董明,任重,余建国,王国利.振动频谱法在架空输电线路张力检测中的应用[J].电网与清洁能源,2012,28(4):12-18. 被引量:6
  • 8DOUGLASS D A, LAWRY D C, EDRIS A A, et al. Dy- namic thermal ratings realize circuit load limits[J]. IEEE Computer Applications in Power, 2000, 13(1): 38-44.
  • 9DOUGLASS D A, EDRIS A A, Real-time monitoring and dy- namic thermal rating of power transmission circuits[J]. IEEE Transactions on Power Delivery, 1996, 11(3):1407-1418.
  • 10徐青松,季洪献,王孟龙.输电线路弧垂的实时监测[J].高电压技术,2007,33(7):206-209. 被引量:75