摘要 碳纤维支杆与金属接头的连接方式通常有两种:胶接和胶-销连接。为了比较二者连接强度的大小,根据当前需求,设计并制作了拉伸试样,然后利用试验机对试样进行了拉伸试验。试验结果表明,胶接方式所能承受的最大拉伸载荷为42.25kN,连接强度为5.83MPa;胶-销连接方式所能承受的最大拉伸载荷为42.10kN,连接强度为5.81MPa。与胶接相比,胶-销连接对支杆和接头的连接强度没有较明显的提升,反而略有下降。 At present ,truss structures are used in most of the space camera structure. Generally, truss structures are composed of benches, truss rods and ends. Most of truss rods are made of carbon fabric composites, and most of ends are made of metal. There are two kinds of modes of joints between carbon fabric rod and metal end : bonded joints and bonded-pinned joints. In order to compare the strength of the joint between bonded joints and bonded-pinned joints, two kinds of tensile samples are designed and manufactured based on current requirements. Then, tensile test was done. The results show that: the maximum tensile load that bonded joints can bear was 42.25kN, joints strength was 5.83MPa; the maximum tensile load that bonded-pinned joints can bear was 42. 10kN, joints strength was 5.81MPa. Compared to bonded joints, bonded-pinned joints did not distinctly increase joints strength, but the strength was reduced merely. Test results lay the foundation for subsequent research.
出处 《玻璃钢/复合材料》 CAS CSCD 北大核心 2014年第5期46-50,8,共6页 Fiber Reinforced Plastics/Composites
关键词 碳纤维支杆 金属接头 胶接 胶-销连接 拉伸试验 carbon fabric rod metal end bonded joints bonded-pinned joints tensile test
  • 相关文献

参考文献15

二级参考文献62

共引文献118

同被引文献13

引证文献2

二级引证文献2