期刊文献+

Effect of prolonging interval time between coronary angiography and percutaneous coronary intervention on X-ray-induced DNA double-strand breaks in blood lymphocytes

Effect of prolonging interval time between coronary angiography and percutaneous coronary intervention on X-ray-induced DNA double-strand breaks in blood lymphocytes
原文传递
导出
摘要 Background It is desirable to minimize the risk of adverse radiation effects associated with percutaneous coronary intervention.The aim of this study was to determine the impact of prolonging the interval between coronary angiography and percutaneous coronary intervention on X-ray-induced DNA double-strand breaks in blood lymphocytes using γ-H2AX immunofluorescence microscopy.Methods Blood samples of eight patients were taken before the first exposure to ionizing radiation,10 minutes,20 minutes,30 minutes,1 hour,and 24 hours after the last exposure to determine the γ-H2AX foci repair kinetics.Fifty-eight patients undergoing percutaneous coronary intervention were randomized to an intermittent radiation exposure group and a continuous radiation exposure group.Blood samples were taken before coronary angiography and 15 minutes after the last exposure.By enumerating γ-H2AX foci,the impact of prolonging the interval on DNA double-strand breaks was investigated.Student t-test was used to compare the difference in DNA double-strand breaks between the two groups.Results An increase in foci was found in all patients received percutaneous coronary intervention.The maximum number of γ-H2AX foci was found 10-20 minutes after the end of the last exposure.There was no statistically significant difference between the two groups in γ-H2AX foci at baseline.On average there were (0.79±0.15) γ-H2AX foci induced by interventional X-rays per lymphocyte in the continuous radiation exposure group and (0.66±0.21) in the intermittent radiation exposure group after exposure (P〈0.05).Conclusions A significant number of γ-H2AX foci develop following the percutaneous coronary intervention procedures.The number of X-ray-induced DNA double-strand breaks may be decreased by prolonging the interval time between coronary angiography and percutaneous coronary intervention to 30 minutes. Background It is desirable to minimize the risk of adverse radiation effects associated with percutaneous coronary intervention.The aim of this study was to determine the impact of prolonging the interval between coronary angiography and percutaneous coronary intervention on X-ray-induced DNA double-strand breaks in blood lymphocytes using γ-H2AX immunofluorescence microscopy.Methods Blood samples of eight patients were taken before the first exposure to ionizing radiation,10 minutes,20 minutes,30 minutes,1 hour,and 24 hours after the last exposure to determine the γ-H2AX foci repair kinetics.Fifty-eight patients undergoing percutaneous coronary intervention were randomized to an intermittent radiation exposure group and a continuous radiation exposure group.Blood samples were taken before coronary angiography and 15 minutes after the last exposure.By enumerating γ-H2AX foci,the impact of prolonging the interval on DNA double-strand breaks was investigated.Student t-test was used to compare the difference in DNA double-strand breaks between the two groups.Results An increase in foci was found in all patients received percutaneous coronary intervention.The maximum number of γ-H2AX foci was found 10-20 minutes after the end of the last exposure.There was no statistically significant difference between the two groups in γ-H2AX foci at baseline.On average there were (0.79±0.15) γ-H2AX foci induced by interventional X-rays per lymphocyte in the continuous radiation exposure group and (0.66±0.21) in the intermittent radiation exposure group after exposure (P〈0.05).Conclusions A significant number of γ-H2AX foci develop following the percutaneous coronary intervention procedures.The number of X-ray-induced DNA double-strand breaks may be decreased by prolonging the interval time between coronary angiography and percutaneous coronary intervention to 30 minutes.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第11期2058-2062,共5页 中华医学杂志(英文版)
关键词 heart catheterization RADIATION DNA double-strand breaks time factors heart catheterization radiation DNA double-strand breaks time factors
  • 相关文献

参考文献23

  • 1Fetterly KA, Lennon RJ, Bell MR, Holmes DR Jr, Rihal CS. Clinical determinants of radiation dose in percutaneous coronary interventional procedures: influence of patient size, procedure complexity, and performing physician. J Am Coll Cardiol Intv Interv 2011; 4: 336-343.
  • 2Fetterly KA, Mathew V, Lennon R, Bell MR, Holmes DR Jr, Rihal CS. Radiation dose reduction in the invasive cardiovascular laboratory implementing a culture and philosophy of radiation safety. JAm Coll Cardiol Intv 2012; 5: 866-873.
  • 3Geijer H, Beckman KW, Andersson T, Persliden J. Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI). Ⅱ. Clinical evaluation. Eur Radiol 2002; 12: 2813-2819.
  • 4Kuon E, Glaser C, Dahm JB. Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures. Br J Radiol 2003; 76: 406-413.
  • 5Bozkurt A, Bor D. Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physicianin interventional radiology using the Monte Carlo method. Phys Med Bio12007; 52: 317-330.
  • 6Kuefner MA, Grudzenski S, Schwab SA, Wiederseiner M, Heckmann M, Bautz W, et al. DNA Double-Strand Breaks and their repair in blood lymphocytes of patients undergoing angiographic procedures. Invest Radio12009; 44: 440-444.
  • 7Banchinger M. Quantification of low-level radiation exposure by conventional chromosome aberration analysis. Mutat Res 1995; 339: 177-189.
  • 8Edwards AA, Lindholm C, Darroudi F, Stephan G, Romm H, Barquinero J, et al. Review of translocations detected by FISH for retrospective biological dosimetry applications. Radiat Prot Dosimetry 2005; 113: 396-402.
  • 9Geisel D, Heverhagen JT, Kalinowski M, Wagner HJ. DNA double-strand breaks after percutaneous transluminal angioplasty. Radiology 2008; 248: 852-859.
  • 10Kuefner MA, Grudzenski S, Hamann J, Achenbach S, Lell M, Anders K, et al. Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography. Eur Radiol 2010; 20: 2917-2924.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部