基于对 TCSC次同步频率等效阻抗特性的研究 ,分析了 TCSC次同步频率等效电阻和等效电抗对抑制次同步谐振 (SSR)的不同作用。发现系统中 SSR的抑制主要取决于 TCSC的次同步频率等效电抗特性 ,而 TCSC的次同步频率等效电阻对 SSR的抑制本质上是一个能量转换过程 ,它只能在一定程度上削弱 SSR,不可能彻底消除 SSR。
Based on the research of equivalent impedance characteristic of TCSC under sub-synchronous frequencies, this paper analyzes the mitigation effect on SSR respectively by TCSC equivalent resistance and TCSC equivalent reactance under sub-synchronous frequencies. It is found that the mitigation of SSR in the system is determined by the sub-synchronous equivalent reactance of TCSC; whereas the mitigation effect on SSR by TCSC equivalent resistance is essentially an energy conversion process, through which SSR can only be mitigated to some extent, rather than completely removed.
出处
《电力系统自动化》
EI
CSCD
北大核心
2002年第2期18-21,44,共5页
Automation of Electric Power Systems
基金
国家自然科学基金重点基金 (5 96 370 5 0
关键词
可控串联补偿
次同步谐振
TCSC
电力系统
Computer simulation
Frequency domain analysis
Resonance
Synchronization