期刊文献+

烟气制酸吸收塔酸温控制系统改造

Reformation of Smelting Off-gases Acid Absorption Tower Acid Temperature Control System
下载PDF
导出
摘要 在烟气制酸过程中,吸收塔入塔酸温过低在吸收过程中会生成酸雾,影响吸收效果,降低吸收率。通过对吸收塔泵槽出口管道进行改造,使制酸系统在单台炉窑作业烟气量小、SO2浓度低等条件吸收酸温度仍可控制在正常范围,保证吸收塔有较高吸收率。 In the process of sulphuric acid making from off-gas,the acid mist will be generated in the process of absorption because of the too low absorption acid temperature,the absorptivity effect is influenced,the absorption rate is reduced. Through reforming the conduit of the absorption tower pump tank outlet,the absorption acid temperature can be controlled in the normal range when single furnace operating on low SO2and small amount of gas conditions,the absorption tower with high absorptivity can be ensured.
作者 周圣兵
出处 《铜业工程》 CAS 2014年第3期45-48,共4页 Copper Engineering
关键词 烟气制酸 吸收 入塔酸温 控制系统 改造 off-gas sulphuric acid generation absorption the acid temperature of into the tower control system reformation
  • 相关文献