摘要
在阐述串补装置平台故障保护原理的基础上,分析了一起由于保护采样回路元件损坏导致平台故障保护动作的原因,并进行了验证试验,指出了现有保护采样数据传输方式、逻辑存在的问题,有针对性地提出改进采样数字传输方式和修改保护逻辑的措施。
The principle of series compensation platform fault protection is presented.The reason of platform fault protection action resulted from fault sample element is presented.The exiting platform fault protection has problems at the respects of sample data transmission mode and the logic of protection.Corresponding improved solutions are put forward for improving digital transmission mode modifying protection logic.
出处
《陕西电力》
2014年第3期67-69,共3页
Shanxi Electric Power
关键词
串补装置
保护
分析
措施
series compensation
protection
analyze
measures