期刊文献+

子宫内膜容积和内膜下血流对子宫内膜容受性影响的比较 被引量:17

Impacts of endometrial volume and endometrial blood flow on endometrial receptivity
下载PDF
导出
摘要 目的探讨子宫内膜容积和子宫内膜下血流情况对子宫内膜容受性的影响。方法应用经阴道二维彩色多普勒及三维容积成像,对138例拟行体外受精一胚胎移植技术(IVF-ET)的不孕症患者于控制性超促排卵周期中移植日进行子宫内膜容积及子宫内膜下螺旋动脉血流搏动指数(PI)、血流阻力指数(RI)进行测量。根据妊娠结果将138例患者分为妊娠组(55例)和非妊娠组(83例),比较两组间相关参数的差异。结果妊娠组子宫内膜容积与非妊娠组比较,无统计学差异(P>0.05);妊娠组子宫内膜下螺旋动脉的PI及RI均低于非妊娠组,两组比较,差异均有显著统计学意义(P<0.01)。子宫内膜容积及内膜下螺旋动脉PI、RI预测妊娠的ROC曲线下面积分别为0.569、0.729、0.717。结论子宫内膜下血流情况在子宫内膜容受性方面起重要的作用,对IVF-ET的妊娠率影响更大。 Objective To compare the impacts of endometrial volume and endometrial blood flow on endometrial receptivity.Methods A total of 138 infertility patients ready to receive in vitro fertilization-embryo transfer (IVF-ET) underwent the measurement of endometrial volume and pulsatility index (PI) and resistance index (RI) of endometrial spiral artery in the controlled ovarian hyperstimulation cycles during the day of transplantation via transvaginal two-dimensional color Doppler and three-dimensional volume imaging.The patients were divided into pregnant group (n =55) and non-pregnant group (n =83),and the related parameters were compared between them.Results Endometrial volume was of no significant difference between the two group (P > 0.05).PI and RI of endometrial spiral artery were significantly lower in the pregnant group than in the non-pregnant group (P < 0.01).The areas under ROC curve of endometrial volu me and endometrial spiral artery PI and RI were 0.569,O.729 and 0.717.Conclusion Endometrial blood plays an important role in terms of endometrial receptivity,and the effect on IVF-ET pregnancy rate is large.
机构地区 解放军第
出处 《临床军医杂志》 CAS 2015年第4期388-390,396,共4页 Clinical Journal of Medical Officers
关键词 子宫内膜容积 子宫内膜下螺旋动脉 血流搏动指数 血流阻力指数 endometrial volume endometrial spiral artery pulsatility index resistant index
  • 相关文献

参考文献10

二级参考文献61

  • 1张宜生,周馥贞,应伟雯.三维超声测定子宫内膜容积预测IVFET结局[J].实用妇产科杂志,2005,21(6):375-377. 被引量:10
  • 2张清学,邢卫杰,文艳玲,李予,罗葆明,杨冬梓.彩色超声多普勒评价子宫内膜容受性的价值[J].中国超声医学杂志,2006,22(5):375-377. 被引量:11
  • 3王丽娜,乔杰,李蓉,刘平,刘朝晖,赵淑云.应用彩色多普勒能量图检测子宫内膜血流评价IVF-ET结局[J].中国微创外科杂志,2006,6(11):857-860. 被引量:28
  • 4Zhang X,Chen CH,Confino E,et al.Increased endometrial thickness is associated with improved treatment outcome for selected patients undergoing in vitro fertilization-embryo transfer.Fertil Steril,2005,83:336-340.
  • 5Schild R,Knobloch C,Dorn C,et al.Endometrial receptivity in an in vitro fentilization program as assessed by spiral artery blood flow,endometrial thickness,endometrial volume,and uterine artery blood flow.Fertil Steril,2001,75:361-366.
  • 6Yaman C,Ebner T,Sommergruber M,et al.Role of threedimensional ultrasonographic measurement of endometrium volume as a predictor of pregnancy outcome in an IVF-ET program:a preliminary study.Fertil Steril,2000,74:797-801.
  • 7Adakan S,Yoldemir T,Tavmergen E,et al.Predictivity of uterine artery,arcuate artery,and intraovarian artery Doppler indices measured on the day of human chorionic gonadotropin injection on pregnancy outcome.Fertil Steril,2005,84:529-532.
  • 8Schild RL,Holthaus S,d Alquen J,et al.Quantitative assessment of subendometrial blood flow by three-dimensional-ultrasound is an important predictive factor of implantation in an in-vitro fertilization program.Hum Reprod,2000,15:89-94.
  • 9Kupesic S,Bekavac I,Bjelos D,et al.Assessment of endometrial receptivity by transvaginal color Doppler and three-dimensional power Doppler ultrasonography in patients undergoing in-vitro fertilization procedures.J Ultrasound Med,2001,20:125-134.
  • 10Wu HM,Chiang CH,Huang HY,et al.Detection of the subendometrial vascularization flow index by three-dimensional ultrasound may be useful for predicting the pregnancy rate for patients undergoing in vitro fertilization embryo transfer.Fertil Steril,2003,79:507-511.

共引文献22

同被引文献117

引证文献17

二级引证文献144

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部