期刊文献+

热泵干燥机变容量控制实验

Experiment on Variable Capacity Control of Heat Pump Dryer
下载PDF
导出
摘要 为了优化热泵干燥机的变容量控制系统,提出了并级模糊控制方法,通过实验对固定频率控制系统、单级模糊控制系统和并级模糊控制系统的动态响应过程进行了研究.分析了3种控制策略在不同设定温度下的控制效果.实验结果表明:与固定频率控制系统和单级模糊控制系统相比,并级模糊控制系统在满足升温速率的前提下,具有上限超调率和下限超调率低以及输出稳定等优点. In order to optimize the variable capacity control system of the heat pump dryer, parallel fuzzy control method was proposed, and the dynamic response processes of fixed frequency control system, single-stage fuzzy control system and parallel fuzzy control system were investigated based on experiments. The performances under different working temperatures were analyzed. The results show that under the condition of meeting the heating rate requirement, parallel fuzzy control system gives a better performance such as lower overshoot rate and undershoot rate, and more stable output compared with fixed frequency control system and single-stage fuzzy control system.
出处 《天津大学学报(自然科学与工程技术版)》 EI CAS CSCD 北大核心 2015年第6期542-546,共5页 Journal of Tianjin University:Science and Technology
基金 国家自然科学基金资助项目(51476111 51276124) 天津市科技计划项目(12ZCDGGX49400) 教育部高等学校博士学科点专项科研基金资助项目(20130032130006)
关键词 热泵干燥机 变容量控制系统 并级模糊控制 heat pump dryer variable capacity control system parallel fuzzy control