文中阐述了塔器壳体开孔补强计算中,计入内部介质压力载荷、风载荷、地震载荷、偏心载荷、设备保温及梯子平台载荷等的计算方法,并通过工程实例分析采用该方法的开孔补强计算结果,以确保塔器设计的本质安全。
This paper set forth a calculation method for pressure load,wind load,seismic load,eccentric load and ladderplatform load which are introduced in the tower shell opening reinforcement calculation,and used engineering examples toanalyze the opening reinforcement calculation result of this method to ensure the intrinsic safety of the tower design.