HSC加速器的初步大功率加速实验

Initial High Power Test of HSC Type Linac
下载PDF
导出
摘要 混合单腔(HSC)型直线加速器是将一段4杆型射频四极(RFQ)加速结构和一段交叉指(IH)型漂移管(DT)加速结构混合到一个IH型腔里,利用IH型腔体具有的低功耗加速梯度高的优点,使得整个IH型混合腔的加速功率效率较其他加速结构腔体的更高。本文进行了低功率测试和初步大功率C6+加速实验。结果显示低功率测试结果与计算结果吻合较好,初步的大功率测试结果表明HSC加速器能满足下一步的高功率实验。 A novel hybrid single cavity (HSC) linac, formed by combining a radio fre- quency quadrupole (RFQ) structure and a drift tube (DT) structure into one interdigi- tal-H (IH) cavity, was fabricated, assembled and tested as a proof of principle type injector for cancer therapy synchrotron. The HSC linac is a power-efficient cavity. The low power test and the high power acceleration test were carried out. The low power test results are in good agreement with the calculation results. The high power test results show that the HSC linac can meet the high power test in the next step.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2015年第B10期569-572,共4页 Atomic Energy Science and Technology
基金 国家自然科学基金资助项目(1103Y536060) 中国科学院创新项目资助(90Y436070)
关键词 RFQ IH结构 漂移管 混合型 重离子注入器 RFQ IH structure drift tube hybrid heavy ion injector
  • 相关文献

参考文献6

  • 1钱炜.中国癌症近年来高发:每6分钟就有一人被确诊[EB/OL].[2014-08-16].http://news.qq.com/a/20130408/001003一a11.htm.
  • 2Hosiotal[Eg/OL]. [2014-07-15]. http://www. nirs. go. jp/ENG/core/hospital/hospitai, shtml.
  • 3Process of heavy ion therapy[EB/OL]. [2014- 05-14]. http: //heavy-ion. showa, gunma-u, ae. jp/en/.
  • 4LU L, HATTORI T, SHI L, et al. Low power test of a hybrid single cavity linac[C/OL] // Pro- ceedings of IPAC'2014. (2014). http://www.
  • 5JACoW. org. LU L, HATTORI T, HAYASHIZAKI N. De- sign and simulation of C6+ hybrid single cavity linac for cancer therapy with direct plasma injec- tion scheme[J]. Nucl Instrum Methods Phys Res A, 2012, 688: 11-21.
  • 6ITO T, LU L, ISHIBASHI T, et al. Research of hybrid single cavity linac[J]. Nucl Instrum Methods Phys Res B, 2007, 261: 17-20.