期刊文献+

Determination of gold nanoparticles in natural water using single particle-ICP-MS 被引量:1

Determination of gold nanoparticles in natural water using single particle-ICP-MS
下载PDF
导出
摘要 A reliable method for detecting nanoparticles is necessary for the wide application of nanomaterials. Single particle-inductively coupled plasma mass spectrometry(SP-ICP-MS) was investigated to detect the size of gold nanoparticles(Au NPs) in this work. Discrimination of particle signal and iterative algorithm were used to calculate the baseline of particle signal. Influence of dwell time was discussed and 3 ms was selected as dwell time for size detection. Different Au NPs standards(30, 60, 80 and 100 nm) and mixed samples(60 and 100 nm) were determined by SP-ICP-MS and the accuracy was confirmed with reference values. The particle size detection limit was 19 nm in ultrapure water(UP water) and 31 nm in 0.1 μg/L Au^(3+) solution. Stability of Au NPs in ultrapure water and natural water samples was investigated by detecting size variation of AuN Ps. The result shows that Au NPs are stable in aqueous environment for 6 d but degraded after 30 d. A reliable method for detecting nanoparticles is necessary for the wide application of nanomaterials. Single particle-inductively coupled plasma mass spectrometry(SP-ICP-MS) was investigated to detect the size of gold nanoparticles(Au NPs) in this work. Discrimination of particle signal and iterative algorithm were used to calculate the baseline of particle signal. Influence of dwell time was discussed and 3 ms was selected as dwell time for size detection. Different Au NPs standards(30, 60, 80 and 100 nm) and mixed samples(60 and 100 nm) were determined by SP-ICP-MS and the accuracy was confirmed with reference values. The particle size detection limit was 19 nm in ultrapure water(UP water) and 31 nm in 0.1 μg/L Au^3+ solution. Stability of Au NPs in ultrapure water and natural water samples was investigated by detecting size variation of AuN Ps. The result shows that Au NPs are stable in aqueous environment for 6 d but degraded after 30 d.
出处 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第7期1611-1617,共7页 中南大学学报(英文版)
基金 Projects(21407182,21277175)supported by the National Natural Science Foundation of China Project(20120162110019)supported by the Specialized Research Fund for the Doctoral Program of Higher Education of China
关键词 single particle-lCP-MS gold nanoparticle size distribution detection stability aqueous environment 电感耦合等离子体质谱法 金纳米粒子 测定精度 天然水 单粒子 停留时间 检测限 纳米材料
  • 相关文献

参考文献2

二级参考文献34

  • 1CPI home. An Inventory Nanotechnology-based Consuner Products Introduced on the Market, http://www.nanotechproject.org/cpi/,2014.
  • 2Tiede K, Hassell?v M, Breitbarth E, Chaudhry Q, Boxall A B. J. Chromatogr. A, 2009, 1216(3): 503-509.
  • 3Gottschalk F, Nowack B. J. Environ. Monit.,2011, 13: 1145-1155.
  • 4Von der Kammer F, Ferguson P L, Holden P A, Masion A,Rogers K R,Klaine S J, Koelmans A A, Horne N,Unrine J M. Environ. Toxicol. Chem., 2012, 31(1): 32-49.
  • 5Gallego-Urrea J A, Tuoriniemi J, Hassell?v M. TrAC, Trends Anal. Chem., 2011, 30(3): 473-483.
  • 6Farré M, Sanchís J, Barceló D. TrAC, Trends Anal. Chem., 2011, 30(3): 517-527.
  • 7Gray E P, Bruton T A, Higgins C P, Halden R U,Westerhoff P, Ranville J F. J. Anal. At. Spectrom., 2012, 27(9): 1532-1539.
  • 8Tiede K, Boxall A B A, Wang X, Gore D, Tiede D, Baxter M, David H, Tear S P, Lewis J. J. Anal. At. Spectrom. , 2010, 25(7) : 1149-1154.
  • 9Degueldre C, Favarger P Y, Bitea C. Anal. Chim. Acta, 2004, 518(1): 137-142.
  • 10Degueldre C, Favarger P Y, Wold S. Anal. Chim. Acta, 2006, 555(2): 263-268.

共引文献21