期刊文献+

R125/R290混合工质热泵制冷剂变流量特性研究 被引量:1

Behavior of heat pump using R125/R290 with variable refrigerant flow rates
原文传递
导出
摘要 对混合工质R125/R290(25/75,质量配比)热泵变制冷剂流量特性进行了实验研究,并以55℃热汇出口温度为例,与被替代工质R134a和R22进行了对比分析。研究结果表明:随着制冷剂流量增大,排气温度线性下降,单位质量制热量则先上升后下降,系统COP随着制冷剂流量的增加表现为先线性增加后缓慢下降的趋势;在混合工质流量为1.12kg/min时,系统出现最大COP值3.040;系统火用效率则随着制冷剂质量流量的增大而增大。整个实验工况范围内,传热温差窄点一直保持在换热器中间部位。实验结果表明,在实验工况范围内,R125/R290(25/75)有望成为R134a及R22的替代工质。 Experimental study of heat pum refrigerant flow rates was carried out, and co p using R125/R290 (25/75 by mass) with variable mpared with that of R134a and R22 under the condition of 55℃ heat sink outlet temperature. The results indicate that, with refrigerant flow rate increasing, the discharge temperature linearly decreases, the heating capacity increases first and then decreases, and the coefficient of performance (COP) increases linearly and then decreases slightly when the refrigerant flow rate is 1.12 kg/min. A peak value of COP was obtained, and the exergy efficiency of the system increases with the refrigerant flow rate increasing. Meanwhile, the pinch point of heat transfer temperature always keeps in the middle of the heat exchanger. The results also show that, the new eco-friendly binary refrigerant is a promising substitute for R134a and R22 used in heat pumps, which are of significance for the application of heat pump using R125/R290 under variable conditions.
出处 《热科学与技术》 CAS CSCD 北大核心 2016年第3期220-226,共7页 Journal of Thermal Science and Technology
基金 国家自然科学基金资助项目(U1504501) 河南省高校青年骨干教师资助项目(2014GGJS-089) 河南省高校重点科研资助项目(15A560014)
关键词 R125/R290(25/75) 热泵 制冷剂变流量 系统性能 R125/R290 (25/75 by mass) heat pump variable refrigerant flow rate COP
  • 相关文献

参考文献15

  • 1吴荣华,刘敏,杨启容.热泵系统输送能耗比例及系统优化[J].热科学与技术,2015,14(5):387-391. 被引量:1
  • 2IEA Heat Pump Center. How heat energy savings and C(), emissions pumps achieve reduction : An introduction. 2011 [EB/OL]. http..//www, heat- pumpcentre, org/en/aboutheatpumps/howheat-pum- psachieveenergysavings/Sidor/default, aspx, 2011.
  • 3马一太,田华.制冷空调关键节能减排技术的现状及进展[J].机械工程学报,2009,45(3):49-56. 被引量:24
  • 4中华人民共和国科学技术部.国家中长期科学和技术发展规划纲要(2006-2020)[EB/OL].http://WWW.most.gov.cn/kjgh/kjghzcq/,2005.
  • 5陈华,任喜悦,谭凯中,王恒.带相变蓄热小型热泵冷凝热回收性能实验研究[J].热科学与技术,2014,13(4):304-309. 被引量:3
  • 6International Institute for Sustainable Development. Report of the Nineteenth Meeting of the Parties to the Montreal Protocol on Substances that Deplete the O=one Layer [EB/OL]. http://www, iisd. ca/ ozone/mop/19mop/MOP-19-TE, Montreal, Cana- da, 2007.
  • 7张丽,徐士鸣,都萍,杨春光,高红岩,段炼.R290/R744新型混合工质汽-液相平衡研究[J].热科学与技术,2014,13(1):29-33. 被引量:6
  • 8STEIMLE F, SCHMIDT E L. Alternative refriger- ants for refrigeration and air conditioning [C]. Proceedings of 20th International Congress of Refrigeration. Sydney:IIR/IIF, 1999-733.
  • 9SEKAR S J, LAL D M, RENGANARAYANAN S. Improved energy efficiency for CFC domestic refrigerators retrofitted with ozone friendly HFCla4a/HC refrigerant mixture [J]. Internation- al Journal of Thermal Sciences, 2004, 43(3):307- 314.
  • 10SEKHAR S J, LAL D M. HFC134a/HC600a/ HC290 mixture a retrofit for CFC12 systems [J]~. International Journal of Refrigeration, 2005, 28(5) ..735-743.

二级参考文献68

共引文献36

同被引文献31

引证文献1

二级引证文献1