摘要 采用吹脱-Fenton氧化法对某制药厂头孢类废水进行预处理,综合考察了各种因素对处理效果的影响。结果表明:氨氮吹脱实验中,在pH值为12,反应温度35℃,吹脱时间120min,气液比1 800下,废水的氨氮去除率可达到95.4%;Fenton氧化出水最优工艺条件为pH值4,反应时间60min,n(Fe^(2+))/n(H_2O_2)为1/3,H_2O_2的投入量20mL·L^(-1),此时,CODCr去除率为40.8%。制药废水经预处理后,废水的可生化性由初始的0.16上升至0.55,生化性显著提高,为后续生化处理提供了有利条件。 The pharmaceutical wastewater of Cephalosporin was pretreated by ammonia blowing-Fenton oxidation,and the effects of various factors on the treatment efficiency were investigated Synthetically.The results show that the removal rate of ammonia-nitrogen could reach 95.4%at the pH value of 12,temperature of 35℃,blowing time of120 min,air-liquid ratio of 1 800 on the experiment of ammonia blowing.The optimal technological conditions for Fenton oxidation experiment were obtained as the pH value of 4,reaction time of 60 min,n(Fe^2+)/n(H2O2)of 1/3,H2O2 dosage of 20mL·L^-1,and the removal rate of CODCrcould reach 40.8%.After the pretreatment,the pharmaceutical wastewater′s biodegradability has increased obviously from the initial 0.16to0.55,which provided advantages for the subsequent biochemical treatment.
作者 彭人勇 谢晓梅 PENG Renyong XIE Xiaomei(College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao 266042, Chin)
出处 《青岛科技大学学报(自然科学版)》 CAS 2016年第5期502-507,共6页 Journal of Qingdao University of Science and Technology:Natural Science Edition
关键词 头孢制药废水 氨氮吹脱 FENTON氧化 预处理 Cephalosporin pharmaceutical wastewater ammonia blowing Fenton oxidation pretreatmen
  • 相关文献

参考文献11

二级参考文献89

共引文献852

同被引文献2

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部