摘要 根据齐鲁供排水厂乙烯污水处理场的2”回用水装置为数据来源,对反渗透膜的运行优化进行分析。通过反渗透膜的污染分析及解决措施,总结了反渗透膜在回用水方面的运行管理注意事项。 Optimization and analysis on running of the reverse penetration membrane were made basing on data scourse from the No. 2 recycle water device in the sewage treatment field for ethylene unit of Qilu Water Supply and Drainage Plant. Notice items on operation and management of the reverse peneration membrane for treatment of the recycle water were summarized basing on pollution analysis and treatment measures of the reverse penetration membrane.
作者 刘俊萍 Liu Junping(Water Supply and Drainage Plant of Qilu Branch Co. , SINOPEC, Zibo Shandong 255411)
出处 《齐鲁石油化工》 2016年第4期305-308,325,共5页 Qilu Petrochemical Technology
关键词 反渗透膜 膜污染 膜清洗 reverse penetration film pollution of membrane clean of membrane
  • 相关文献

参考文献1

二级参考文献15

  • 1王宇彤.反渗透膜的污染与清洗[J].化学清洗,1996,12(1):14-18. 被引量:6
  • 2[2]KONSUTIC K,KUNST B.RO and NF membrane fouling and cleaning and pore size distribution variation[J].Desalination,2002,150:113-120.
  • 3[4]GWONA E M,YUB M J,OH H K,et al.Fouling characteristics of NF and RO operated for removal of dissolved matter from groundwater[J].Water Research,2003,37:2989 -2997.
  • 4[5]ANG W S,LEE S,ELIMELECH M.Chemical and physical aspects of cleaning of organic-fouled reverse osmosis membranes[J].Journal of Membrane Science,2006,272:198-210.
  • 5[6]JOSE J.SADHWANI,JOSE M V.Cleaning tests for seawater reverse osmosis membranes[J].Desalination,2001,139:177-182.
  • 6[7]TESSARO I C,SILVA J B A D,WADA K.Investigation of some aspects related to the degradation of polyamide membranes:aqueous chlorine oxidation catalyzed by aluminum and sodium laurel sulfate oxidation during cleaning[J].Desalination,2005,181:275-282.
  • 7[8]SAYED S M,TORAJ M,MANSOUR K M.Chemical cleaning of reverse osmosis membranes[J].Desalination,2001,134:77-82.
  • 8[9]MADAENI S S,MANSOURPANAH Y.Chemical cleaning of reverse osmosis membranes fouled by whey[J].Desalination,2004,161:13-24.
  • 9[10]JUNG Y J,KISO Y,YAMADA T,et al.Chemical cleaning of reverse osmosis membranes used for treating wastewater from a rolling mill process[J].Desalination,2006,190:181-188.
  • 10[12]CHEN J.PAUL,KIM S.L,TING Y.P.Optimization of membrane physical and chemical cleaning by a statistically designed approach[J].Journal of Membrane Science,2003,219:27-45.