期刊文献+

脱盐废水中钙镁离子脱除技术的研究 被引量:4

Study on the Technology of Removing Calcium and Magnesium Ions in Wastewater Desalination
下载PDF
导出
摘要 以"烧碱-纯碱"的方法对脱盐废水中钙镁离子的脱除进行了研究,以原子吸收分光光度计测定脱除前后的钙镁离子含量。采用正交试验法探讨了温度、两碱用量、反应时间、陈化时间四个因素对钙镁离子脱除率的影响,综合比较找出了最优条件:25℃下,两碱用量为理论量的1.2~1.4倍,反应时间为1h,陈化时间为2h,此条件下钙镁离子脱除效果最好,钙离子脱除率达96%以上,镁离子脱除率平均可达90%。 The method of "caustic soda, soda ash" to remove the calcium and magnesium ions in desahing waste water has been studied. Determination of calcium and magnesium ions by flame atomic absorption spectrometry has been reviewed. The method of orthogonal test is used to study the influence to the removal rate of the calcium and magnesium ions caused by temperature, the dosage of two alkali, reaction time and aging time etc. Though comprehensive comparison the optimal conditions has been found out: under 25℃, the dosage of alkali is 1.2-1.4 times the amount of theory, the reaction time is 1 h, aging time is 2h, under these conditions the best removal of calcium and magnesium ions is achieved, and the removal rates of calcium and magnesium ions are 96% and 90%, respectively.
作者 胡洁 杨玉敏 臧红霞 朱亚亭 HU Jie YANG Yu-min ZANG Hong-xia ZHU ya-ting(Xingtai College, Xingtai 054001, China)
机构地区 邢台学院
出处 《安徽化工》 CAS 2017年第1期26-29,32,共5页 Anhui Chemical Industry
基金 邢台市科技支撑计划项目(2015ZC052)
关键词 脱盐废水 两碱法 钙离子 镁离子 desalination wastewater two alkaline method calcium ions magnesium ions
  • 相关文献

参考文献11

二级参考文献48

共引文献99

同被引文献35

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部