期刊文献+

燃煤电厂湿烟气的除湿特性 被引量:20

Dehumidification performance of wet flue gas in coal-fired power plant
下载PDF
导出
摘要 燃煤电厂湿法脱硫后排放的烟气中含有大量水蒸气,造成大量水资源的浪费,溶液除湿工艺是水分回收技术之一。通过绝热型管式降膜除湿试验台,采用价格低廉的CaCl_2溶液为除湿剂,探究了湿烟气状态下溶液浓度、溶液温度、传质面积及进口温度对除湿性能的影响,试验得到了CaCl_2溶液除湿过程的传质系数,溶液除湿效率远高于清水冷凝除湿,为烟气除湿工艺的选择和性能预测提供了参考。 The flue gas after FGD emitted in coal-fired power plant contains a large amount of water vapor,which means a great waste of water resources. The liquid desiccant-based dehumidification is a feasible technology to recover water from flue gas. To study the dehumidification performance of this technology, a laboratory scale adiabatic tube falling film dehumidifier was built with CaCl2 solution as desiccant. The performance of this technology and the effect of solution temperature, concentration, mass transfer area and air inlet temperature was investigated. The mass transfer coefficient was given by 0.009—0.040 m·s-(-1). Moreover, a comparison between condensation and liquid desiccant-based dehumidification was carried out. The data showed that the water recovery efficiency would be more than 50%, which was much better than condensation method and confirmed the feasibility of this technology applied in power plants.
出处 《化工学报》 EI CAS CSCD 北大核心 2017年第9期3558-3564,共7页 CIESC Journal
基金 国家重点研发计划项目(2017YFF0209800) 山东省重点研发计划项目(2016GGX104009)
关键词 烟道气 吸收 除湿 水溶液 管式降膜 flue gas absorption water recovery solution tube falling film