给出了潍坊发电厂300MW机组励磁系统及PSS的数学模型和参数。试验结果表明,仿真计算与现场试验相结合是确定PSS 参数既有效又易于实现的方法。用频率法设计PSS参数,可使PSS具有较好的频率适应性。
The mathematical model and parameters of the excitation system of a 300MW generating set and its PSS are given. Test results show that to determine the parameters of PSS it is an effective and easy method to combine thesimulation calculation with on-site testing. If the PSSparameters are designed by frequency method the PSS may possess better frequency adaptability.
出处
《电网技术》
EI
CSCD
北大核心
2002年第9期29-32,共4页
Power System Technology