摘要
以变压器-套管体系振动台试验模型作为参照对象,建立了基于ANSYS有限元软件的精细化模型,模拟了典型工况下的振动台试验,将模拟结果与试验结果进行了对比研究,分析了模拟结果的相对偏差。
Based on the vibration table test model of transformer-bushing system, the model based on ANSYS finite element software is established. The shaking table test under typical operating conditions is simulated. The simulation results are Compared with the experimental results, and the relative deviation of the simulation results is analyzed.
出处
《变压器》
北大核心
2017年第11期49-55,共7页
Transformer
关键词
变压器-套管体系
试验
数值模拟
相对偏差
Transformer-bushing system
Test
Numerical simulation
Relative deviation