期刊文献+

Experimental measurement of tip vortex flow field with/without cavitation in an elliptic hydrofoil 被引量:16

Experimental measurement of tip vortex flow field with/without cavitation in an elliptic hydrofoil
原文传递
导出
摘要 In this paper, recent measurements of tip vortex flow with and without cavitation carried out in Cavitation Mechanism Tunnel of China Ship Scientific Research Center(CSSRC) are presented. The elliptic hydrofoil with section NACA 662-415 was adopted as test model. High-speed video(HSV) camera was used to visualize the trajectory of tip vortex core and the form of tip vortex cavitation(TVC) in different cavitation situations. Laser Doppler velocimetry(LDV) was employed to measure the tip vortex flow field in some typical sections along the vortex trajectory with the case of cavitation free. Stereo particle image velocimetry(SPIV) system was used to measure the velocity and vorticity distributions with and without cavitation. Series measurement results such as velocity and vorticity distributions, the trajectory of tip vortex core, the vortex core radius, cavity size and cavitation inception number were obtained. The results demonstrated that the minimum pressure coefficient in the vortex core obtained by flow field measurement was quite coincident with the tip vortex cavitation inception number obtained under the condition of high incoming velocity and low air content. And TVC would decrease the vortex strength comparing with the case without cavitation. In this paper, recent measurements of tip vortex flow with and without cavitation carried out in Cavitation Mechanism Tunnel of China Ship Scientific Research Center(CSSRC) are presented. The elliptic hydrofoil with section NACA 662-415 was adopted as test model. High-speed video(HSV) camera was used to visualize the trajectory of tip vortex core and the form of tip vortex cavitation(TVC) in different cavitation situations. Laser Doppler velocimetry(LDV) was employed to measure the tip vortex flow field in some typical sections along the vortex trajectory with the case of cavitation free. Stereo particle image velocimetry(SPIV) system was used to measure the velocity and vorticity distributions with and without cavitation. Series measurement results such as velocity and vorticity distributions, the trajectory of tip vortex core, the vortex core radius, cavity size and cavitation inception number were obtained. The results demonstrated that the minimum pressure coefficient in the vortex core obtained by flow field measurement was quite coincident with the tip vortex cavitation inception number obtained under the condition of high incoming velocity and low air content. And TVC would decrease the vortex strength comparing with the case without cavitation.
出处 《Journal of Hydrodynamics》 SCIE EI CSCD 2017年第6期939-953,共15页 水动力学研究与进展B辑(英文版)
基金 Project supported by the Key Project of National Natural Science Foundation of China(Grant No.11332009)
关键词 Tip vortex flow field CAVITATION LDV SPIV HSV measurement data Tip vortex, flow field, cavitation, LDV, SPIV, HSV, measurement data
  • 相关文献

参考文献2

二级参考文献11

共引文献54

同被引文献100

引证文献16

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部