摘要
针对丙烯腈装置冷冻机调速器更换后,机组负荷提不起来,通过进行调速器、主调节阀、负荷阀、主断气阀的现场调整试验,以及解体检查冷冻机的过流部件,确认事故原因,彻底清洗和润滑预旋叶片后,使问题得到解决。
The refrigerating skid in acrylonitrile plant couldn′ t reach to the load after changing its speed governor. W e checked on site the speed governors, main control valves, load valves, and main check valves,disassembled the flow passage components, washed and lubricated the prerotation vanes. The problems were solved.
作者
王海峰
高玉国
Wang Haifeng;Gao Yuguo(PetroChina Daqing Branch ,Daqing 163714)
出处
《大氮肥》
CAS
2018年第2期134-135,144,共3页
Large Scale Nitrogenous Fertilizer Industry
关键词
制冷机组
负荷不足
过流部件
预旋叶片
refrigerating skid
insufficient load
flow passage component
prerotation vane