摘要
对GB 50009—2012建筑结构荷载规范中消防车荷载的计算在YJK和PKPM中的实现方法分别进行计算分析,得出结构设计计算中常用的这两种计算软件对消防车载荷的计算具有较大的差异,通过对比分析计算结果可知,与PKPM计算软件相比,YJK软件在计算消防车荷载时工作量更小,计算更加合理,经济性也更好。
This paper calculates the fire truck load by YJK and PKPM,and draw a conclusion that it has large difference on these two ways. The comparison of calculation results show that,it more reasonable and more economical calculating the fire truck load by YJK makes and it requires less work.
作者
冯立燕
牛传凯
Feng Liyan1,Niu Chuankai2,3(1. China Architecture Shanghai Design Research Institute Co. , Ltd, Shanghai 201900, China; 2. College of Civil Engineering, Tongji University, Shanghai 200092, China; 3. Mingyang Intelligent Energy Group Shanghai Co. , Ltd, Shanghai 200235, Chin)
出处
《山西建筑》
2018年第21期43-44,共2页
Shanxi Architecture