摘要
为了研究雷击线路杆塔时埋地油气管道的防护措施对降低防腐层感应电压防护效果的影响,本文通过CDEGS软件建立了埋地油气管道、线路杆塔及接地装置的仿真计算模型,对排流带的布置方位、与管道的连接方式、与管道的距离、排流带的长度对降低防腐层感应电压的效果进行了分析,得到如下结论:排流带靠近杆塔侧敷设比背向杆塔侧敷设效果更优;排流带与管道连接点数量对管道防腐层感应电压影响不大,但管道上排流带连接点与杆塔越接近效果会稍好;排流带与管道之间的距离对管道防腐层感应电压影响不明显,但排流带越靠近管道对降低防腐层感应电压效果会稍好;增加排流带的长度可明显增加对管道沿线防腐层感应电压的防护范围。
In order to study the effect of protective measures of buried oil and gas pipelines on reducing the protective effect of induced voltage of anti-corrosion coatings when lightning strikes line towers,a simulation calculation model of buried oil and gas pipelines,line towers and grounding devices is established by using CDEGS software.The effect of reducing induced voltage of anticorrosive coating by layout orientation of drainage strip,connection mode with pipeline,distance from pipeline and length of drainage strip is analyzed.The following conclusions are drawn:The laying of the drainage belt near the tower side is better than that of the side pole tower.The number of connection points between drainage strip and pipeline has little effect on induced voltage of pipeline anticorrosion coating,but the closer the connection points of drainage strip and tower are,the better the effect will be.The distance between drainage belt and pipeline has no obvious effect on the induced voltage of pipeline anticorrosive coating,but the closer the drainage belt is to the pipeline,the better the effect is.Increasing the length of the discharge belt can significantly increase the protection scope of the induced voltage of the anticorrosive layer along the pipeline.
作者
谭波
童雪芳
张康伟
郭轶磊
王湘汉
陈嫣冉
TAN Bo;TONG Xuefang;ZHANG Kangwei;GUO Yilei;WANG Xianghan;CHEN Yanran(China Electric Power Research Institute,Wuhan 430074,China;State Key Laboratory of Power Grid Environmental Protection,Wuhan 430074,China;College of Electrical Engineering and New Energy,China Three Gorges University,Yichang 443002,China)
出处
《电瓷避雷器》
CAS
北大核心
2019年第2期9-13,共5页
Insulators and Surge Arresters
基金
国家重点研发计划资助(编号:2016YFB0900800)"±1100kV直流输电关键技术研究与示范"
国家电网公司总部科技项目资助(编号:GY71-16-037)"高压直流接地极系统地金属管道的影响与防护研究"
关键词
埋地油气管道
防腐层
雷击线路杆塔
防护措施
防护效果
buried oil and gas pipelines
anticorrosive layer
lightning strike line towers
protective measures
protective effects