摘要 以去离子水为实验介质,对截面为3 mm×43 mm的三面加热窄矩形通道内饱和沸腾(FDB)起始点进行了实验研究。分析了部分热工参数对饱和沸腾起始点的影响,对三面加热窄矩形通道内饱和沸腾起始点的数据进行非线性回归分析,得到适用于三面加热窄矩形通道饱和沸腾起始点热通量的经验关系式。结果表明:新拟合得到的关系式能较准确地预测三面加热窄矩形通道内饱和沸腾起始点的热通量,其预测值的相对误差为15.17%。将新关系式计算结果与现有实验数据进行比较,源于单面加热窄矩形通道的实验数据与新关系式符合程度较好,表明新关系式可适用于单面加热窄矩形通道。 The deionized water was used as the experimental medium,and the fully developed boiling(FDB)starting point of the three-sided heated narrow rectangular channel with a section of3mm×43mm was studied.The influence of some thermal parameters on FDB starting point is analyzed.Empirical correlation of FDB’s heat flux suitable for the three-side heating narrow rectangular channel was obtained by nonlinear regression analysis for experimental data of FDB starting location.The results show that the new empirical correlation can accurately predict heat flux of FDB in the three-side heating narrow rectangular channel.The relative error of predicting value is15.17%.Besides,the simulation results of new empirical correlation are compared with some existing experimental data.The experimental data obtained from one-side heating narrow rectangular channel are in fairly agreement with new empirical correlation.This shows that new empirical correlation is well suited for one-side heating narrow rectangular channel.
作者 周云龙 郭新田 张文超 陈旭 ZHOU Yunlong;GUO Xintian;ZHANG Wenchao;CHEN Xu(College of Energy and Power Engineering,Northeast Electric Power University,Jilin132012,Jilin,China)
出处 《化工学报》 EI CAS CSCD 北大核心 2018年第12期4972-4978,共7页 CIESC Journal
基金 国家自然科学基金项目(51541608 51776033)~~
关键词 三面加热 窄矩形通道 饱和沸腾起始点 两相流 传热 相变 three-side heating narrow rectangular channel FDB starting point two-phase flow heat transfer phase change
  • 相关文献

参考文献7

二级参考文献41

  • 1王甲强,贾斗南,郭赟,严明宇,秋穗正,苏光辉,卢冬华.环形窄通道内过冷沸腾起始点的实验研究[J].核动力工程,2004,25(4):319-323. 被引量:5
  • 2阎昌琪,黄渭堂.用γ射线衰减技术测量两相流空泡份额的实验研究[J].应用科技,1989,16(2):1-7. 被引量:2
  • 3[1]J G Collier, J R Thome. Convective Boiling and Condensation. Third Edition. Oxford University Press, 1994
  • 4[2]Z L Miropolskii, et al. Void Fraction of Water-Steam Mixture Flow with or Without Heat Transfer. Teploenergetika, 1971, (5): (in Russian)
  • 5[3]P Saha, N Zuber. Point of Net Vapour Generation and Vapour Void Fraction in Subcooled Boiling. In: Proc. of the 5th International Heat Transfer Conference. Tokyo,1974. Paper B4.7
  • 6[4]S Levy. Forced Convection Subcooled Boiling Prediction of Vapor Volumetric Fraction. Int. J. Heat Mass Transfer, 1967, 10:951-965
  • 7[5]S C Lee, H Dorra, S G Bankoft. A Critical Review of Predictive Models for the Onset of Significant Void in Forced Convection Subcooled Boiling. Presented at ASME Winter Ann. Mtg. Anaheim, CA, 1992
  • 8[6]H O Chang, J C Chapman. Two-Phase Flow Instability for Low-Flow Boiling in Vertical Heated Thin Rectangular Channels. Nuclear Technology, 1996, 113:327-337
  • 9[1]SUN QI, YANG RUICHANG, ZHAO HUA. Predictive study of the incipient point of net vapor generation in low-flow subcooled boiling[J]. Nucl Engrg Des, 2003,225(2-3):249-256.
  • 10[2]VIJAYAN P K, MARUTHI RAMESH N, PILKHWAL D S, et al. An assessment of void fraction correlations for vertical upward steam-water flow[R]. India: Bhabha Atomic Research Center, 1997.1-12.