期刊文献+

高等级生物安全实验室的自动控制方法 被引量:7

Control method of automatic control system in high-level biosafety laboratories
下载PDF
导出
摘要 介绍了高等级生物安全实验室对自动控制系统的要求。通过对核心工作间、化学淋浴消毒间及防护服更换间管道风量调节阀的分析,分别研究了其压力控制方法。深入分析了通风空调故障情况下的机组切换过程。在生物安全实验室空调自动控制系统正常运行及故障情况下,该控制方法均能够保证实验室压力的稳定及有序的压力梯度。强调了自动控制系统对人员及环境安全的重要性。 Presents the automatic control system requirements in high-level biosafety laboratories. Studies the pressure control method through analysis of the air control valve of the core workshop, chemical shower room and protective clothing replacement room. Analyses the fan switching process in the case of ventilation and air conditioning failure. Concludes that the control method can ensure the stability of laboratory pressure and orderly pressure gradient under the conditions of normal operation and failure. Emphasizes the importance of automatic control system to safety of human and environment.
作者 卜云婷 魏一 邢国华 佟海龙 赵春晖 高阳 吴新洲 王栋 Bu Yunting;Wei Yi;Xing Guohua;Tong HaiHong;Zhao Chunhui;Gao Yang;Wu Xinzhou;Wang Dong
出处 《暖通空调》 2020年第1期25-30,共6页 Heating Ventilating & Air Conditioning
基金 国家重点研发计划课题“安全高效空调通风系统关键技术与系统集成研究”(编号:2018YFC1200304)
关键词 生物安全实验室 自动控制系统 压差 风机 风量调节阀 变频器 biosafety laboratory automatic control system pressure difference fan air control valve inverter
  • 相关文献

参考文献5

二级参考文献17

  • 1陈邝尹.生物安全实验室的暖通系统划分原则[J].洁净与空调技术,2006(1):32-33. 被引量:3
  • 2陈邝尹.生物安全实验室暖通空调系统的几个设计要点[J].暖通空调,2006,36(7):76-77. 被引量:5
  • 3张彦国.生物安全实验室检测中发现的问题.暖通空调标准与质检,2006,(4):8-11.
  • 4邓幼莹.美国生物安全实验室的规划和建筑设计.建筑科学,2005,21:34-44.
  • 5王清勤 张彦国 许钟麟 等.生物安全实验室建筑技术规范介绍.建筑科学,2005,21:1-8.
  • 6张彦国.生物安全实验室的检测.建筑科学,2005,21:149-153.
  • 7张益昭.生物安全实验室设计中需要澄清的问题.建筑科学,2005,21:9-13.
  • 8节流式可变风量空调系统中的一种定风量装置——文氏风阀.周祖毅,译[J].暖通空调,1979,9(1):39.
  • 9Louis J D. Guidelines for laboratory design[M]. 3rded. John Wiley &- Sons, Inc., Publication, 2001.
  • 10ASHRAE. ASHRAE handbook—HVACapplications[M], 2007.