摘要
针对河北省某磷酸企业生活污水磷超标排放问题,采用污水一体化处理装置及相关附属工程进行整治。工程稳定运行两个月后,出水水质指标为:TP≤5 mg/L,CODcr≤300 mg/L,NH 3-N≤25 mg/L,主要污染物指标达到《污水排入城镇下水道水质标准》(GB/T 31962—2015)C级标准。运行结果显示该工程对含磷污水具有良好的处理效果,同时能有效去除有机物及氮等杂质,实现污水的达标排放。并且占地面积小,运行成本低,经济效益显著。
In order to solve the problem of excessive phosphorus discharge in domestic sewage of a phosphoric acid enterprise in Hebei Province,the sewage integrated treatment device and related auxiliary works were adopted.After two months of stable operation of the project,the quality indexes of the treated water are:CODcr≤500 mg/L,NH 3-N≤45 mg/L,TP≤8 mg/L,SS≤400 mg/L,6.5≤pH≤9.5,which conforms to the"quality standard of sewage discharged into urban sewer"(GB/T 31962—2015)grade C standard.The operation results show that the project has a good effect on the treatment of phosphorus wastewater,and can effectively remove impurities such as organic matter and nitrogen,and realize the discharge of sewage to the standard.The project covers a small area and the operation cost is low,which has good comprehensive economic benefits.
作者
汪佳慧
赵明杰
王静
刘晓静
栗勇田
Wang Jiahui;Zhao Mingjie;Wang Jing;Liu Xiaojing;Li Yongtian(Institute of Environmental Science and Engineering,Tianjin University,Tianjin 300072,China;Hebei Key Laboratory of River Water Quality Purification and Ecological Restoration,Qinhuangdao Tianda Environmental Protection Research Institute Co.,Ltd.,Qinhuangdao 066000,China;Qinhuangdao Water Pollution Monitoring and Treatment Engineering Technology Research Center,Qinhuangdao 066000,China)
出处
《山东化工》
CAS
2021年第7期252-253,255,共3页
Shandong Chemical Industry
基金
河北省重点研发计划资源与环境专项(19273905D)
河北省引进国外智力项目(2019YX015B)
河北省创新能力提升计划项目新型研发机构建设专项(19963906D)。
关键词
含磷污水
污水一体化处理装置
达标排放
phosphorus-containing wastewater
sewage integrated treatment unit
discharge up to standard