摘要
主要论述了某厂硫氰酸钠溶剂回收装置中固定管板式换热器发生列管内漏失效的判断方法、处理措施、原因分析及预防措施。其中在未打开设备的前提下对故障判断方法进行了详细论述,通过3种手段判断并确认是否有列管泄漏,以减少不必要的维修费用,对此类固定管板换热器的内漏判断及处理有广泛的借鉴意义。
This paper mainly discussed the determination method,treatment measure,cause analysis and preventive measure of tubulation internal leakage failure of fixed tube-plate heat exchanger in sodium thiocyanate solvent recovery unit of a factory.Among them,without opening the equipment,the fault judgment method was discussed in detail by three means to judge and confirm whether there was the tube leakage,so as to reduce unnecessary maintenance costs,which had a wide range of reference significance for the determination and treatment of internal leakage of such fixed tubule-plate heat exchanger.
作者
李霞
Li Xia(Acrylic Plant of PetroChina Daqing Petrochemical Company,Daqing 163714,China)
出处
《炼油与化工》
CAS
2021年第3期55-56,共2页
Refining And Chemical Industry
关键词
固定管板式换热器
列管
泄漏
故障判断
fixed tube-plate heat exchanger
tubulation
leakage
failure judgement