期刊文献+

外载荷作用下塔器开孔补强计算探讨

Discussion on Calculation of Tower Opening Reinforcement under External Load
下载PDF
导出
摘要 设计塔器时除应考虑内压、外压和液柱静压力外,还应考虑风载荷、地震载荷、偏心载荷、容器自重及管道推力等其他外载荷。当风载荷和地震载荷起主要作用时,按相关标准提供的等面积法(仅考虑压力载荷)进行塔器开孔补强设计有时是不安全的。提出采用组合应力法校核塔器开孔处的强度,并结合工程实例论证了将组合应力法和等面积法相结合进行塔器开孔补强计算的必要性。 For the design of the towers,in addition to internal pressure,external pressure, and liquid column static pressure,other external loads such as wind load,seismic load,eccentric load,vessel self-weight,and pipeline thrust should also be considered. When the tower is mainly affected by wind load and earthquake load,it is not safe for opening reinforcement calculation to use an equal-area method(only considering pressure). The combined stress method was proposed for the strength check of the opening on the towers.Based on engineering examples,the necessity and validity were demonstrated for the calculation of the openings and reinforcement on the tower by a combination of the equal-area method and combined stress method.
作者 袁博 许学斌 王小鹏 YUAN Bo;XU Xue-bin;WANG Xiao-peng(HUALU Engineering&Technology Co.Ltd.,Xi'an 710065,China)
出处 《石油化工设备》 CAS 2022年第6期37-40,共4页 Petro-Chemical Equipment
关键词 塔器 开孔补强 等面积法 组合应力法 计算 tower opening reinforcement equal—area method combined stress method calculation
  • 相关文献

参考文献7

二级参考文献25

  • 1高文彦.化工装置中塔器的风诱导振动[J].化工设备与管道,2001,38(5):29-31. 被引量:5
  • 2.JB 4732—1995.钢制压力容器分析设计标准[S].,..
  • 3.JB 4710—1992.钢制塔式容器[S].,..
  • 4王国强.实用数值模拟技术及其在ANSYS上的实践[M].西安:西北工业大学出版社,1999..
  • 5王泽军 谭蔚.压力容器应力分析中几个问题的讨论[J].压力容器,2001,18:90-94.
  • 6桑如苞.法兰设计.压力容器设计工程师培训教程[M].北京:新华出版社,2005:2222.
  • 7GB150-1998.钢制压力容器[S].[S].北京:国家技术监督局,1998..
  • 8JB/T 4710-2005 钢制塔式容器[S].北京:国家发展和改革委员会,2005.
  • 9寿比南,陈钢.GB150.3—2011压力容器[S].北京:中国标准出版社,2012:93-183.
  • 10张延丰,杨国义,王者相,等.NB/T47041-2014塔式容器[s].北京:新华出版社,2014:24-25.

共引文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部