摘要
盐城市某造纸废水处理厂处理规模为3.5×10^(4)m^(3)/d,原设计排放标准为《城镇污水处理厂污染物排放标准》(GB18918-2002一级B标准)TN执行《制浆造纸工业水污染物排放标准》(GB3544-2008)表2制浆造纸联合生产企业标准,本次提标及技改项目将原气浮系统改造为粉末活性炭-磁混凝沉淀系统,改造后排放标准达到《城镇污水处理厂污染物排放标准》(GB18918-2002)一级A标准TN执行《制浆造纸工业水污染物排放标准》(GB3544-2008)表3制浆造纸联合生产企业标准)。
The treatment scale of a papermaking wastewater treatment plant in Yancheng City is 3.5×10~4 m~3/d, The original design emission standard was 《Pollutant discharge standards for urban sewage treatment plants》(GB18918-2002)Level 1 B standard(TN executes 《Discharge standards for water pollutants in the pulp and paper industry》(GB3544-2008)table 2 pulp and paper joint production enterprise standards), the bid raising and technical transformation project transformed the original air flotation system into a powder activated carbon-magnetic coagulation precipitation system, after the renovation, the emission standards are met 《Pollutant discharge standards for urban sewage treatment plants》(GB18918-2002)Level 1 A standard(TN executes 《Discharge standards for water pollutants in the pulp and paper industry》(GB3544-2008)table 3 pulp and paper joint production enterprise standards).
作者
房燕
贾伯林
朱忠华
周悦
张腾
Fang Yan;Jia Bolin;Zhu Zhonghua;Zhou Yue;Zhang Teng(Water department Jiangsu Jingyuan Environmental Protection Co.,Ltd.,Nantong 226001,China)
出处
《广东化工》
CAS
2022年第24期183-186,共4页
Guangdong Chemical Industry
关键词
造纸
气浮池
提标改造
活性炭
磁混凝
平流沉淀池
papermaking
air flotation tanks
improve effluent quality and remodel
activated carbon
magnetic condensation