摘要
目的 对比分析闭式体外循环下微创主动脉瓣膜置换术(MIS-AVR)与经导管主动脉瓣置换术(TAVR)对主动脉瓣病变患者疗效的影响。方法 选取2021年5月至2022年6在该院接受治疗的主动脉瓣病变患者108例,根据手术类型将其分为TAVR组(n=54,行TAVR治疗)和MIS-AVR组(n=54,行MIS-AVR治疗)。比较2组患者临床疗效、围手术期指标、炎症因子水平、心功能指标及并发症发生情况。结果 MIS-AVR组患者总有效率为98.15%(53/54),与TAVR组的96.30%(52/54)比较,差异无统计学意义(P>0.05);MIS-AVR组患者伤口大小、手术时间、术中输血量、住院时间均显著高于TAVR组,差异均有统计学意义(P<0.05);治疗后,2组患者细胞间黏附分子1、单核细胞趋化蛋白1、长正五聚蛋白3水平,左心室内径、肺动脉收缩压、室间隔厚度、二尖瓣环速度均较治疗前显著降低,且MIS-AVR组低于TAVR组,差异均有统计学意义(P<0.05);MIS-AVR组患者并发症发生率为5.55%(3/54),与TAVR组的9.25%(5/54)比较,差异无统计学意义(P>0.05)。结论 MIS-AVR与TAVR治疗主动脉瓣病变疗效均较好,TAVR操作简单,对围手术期患者创伤小,但MIS-AVR对患者炎症因子和心功能的改善较优,且并发症发生率略低。
Objective To compare and analyze the effects of mini-incision aortic valve replacement(MIS-AVR)and transcatheter aortic valve replacement(TAVR)under closed extracorporeal circulation on patients with aortic valvular lesion.Methods A total of 108 patients with aortic valvular lesion who accepted therapy in the hospital from May 2021 to June 2022 were selected and divided into the TAVR group(n=54,TAVR treatment)and the MIS-AVR group(n=54,MIS-AVR treatment)according to the type of surgery.The clinical potency,perioperative indicators,inflammatory factor standards,cardiac ability targets and complications of the two groups were compared.Results The total effective rate of the MIS-AVR group was 98.15%(53/54),compared with 96.30%(52/54)in the TAVR group,the difference was not statistically significant(P>0.05).The slash size,surgery time,intraoperative blood transfusion and length of stay at hospital in the MIS-AVR group were significantly higher than those in the TAVR group,and the differences were statistically significant(P<0.05).After treatment,the levels of intercellular adhesion molecule-1,monocyte chemoattractant protein-1,long-term pentraxin-3,left ventricular diameter,pulmonary artery systolic pressure,interventricular septum thickness and mitral annulus velocity in the two groups were significantly lower than those before treatment,and the MIS-AVR group were less than those in the TAVR group,and the differences were statistically significant(P<0.05).The incidence of complications in the MIS-AVR group was 5.55%(3/54),and there was no significant difference compared with 9.25%(5/54)in the TAVR group(P>0.05).Conclusion MIS-AVR and TAVR are both effective in the treatment of aortic valvular lesion.TAVR is easy to operate and has less trauma to perioperative sicks.However,MIS-AVR has better improvement in inflammatory factors and cardiac function,and the syndromes are slightly lower.
作者
刘守印
吴晓
LIU Shouyin;WU Xiao(Department of Cardiovascular Surgery,Nanyang First People′s Hospital,Nanyang,Henan 473000,China)
出处
《现代医药卫生》
2024年第5期793-797,共5页
Journal of Modern Medicine & Health
关键词
闭式体外循环
微创主动脉瓣膜置换术
经导管主动脉瓣置换术
主动脉瓣病变
Closed extracorporeal circulation
Mini-incision aortic valve replacement
Transcatheter aortic valve replacement
Aortic valvular lesion