期刊文献+

三向变形条件下铜片止水破坏准则研究

Failure criterion of copper water-stops under three-dimensional deformation
下载PDF
导出
摘要 铜片止水是水工混凝土结构分缝之间最重要的止水构件。混凝土结构在自重和水荷载作用下,常产生不均匀变形,使结构分缝之间的铜片止水产生拉伸(压缩)、沉陷和剪切三向变形(相对位移)。铜片止水的安全性取决于三向变形的量值,常通过三个方向的位移单独判断,未考虑三向位移的耦合作用。本文设计制作了两种尺寸共计40个铜片止水试件,通过三向加载独立控制的试验平台对铜片止水进行了不同拉伸、沉降位移的剪切试验,研究了铜片止水的剪切变形规律和破坏形态,得到了三维位移空间中的破坏包络面,提出了一个三向变位条件下铜片止水的变形破坏准则,可用于铜片止水的安全性判断。 Copper water-stop is the most important component for preventing water leak through the joints of hydraulic concrete structures.Concrete structures often experience uneven deformation under gravity and hydrostatic pressure,resulting in tension(or compression),settlement,and shear deformation(relative displacement)between the two wings of a copper water-stop.Its safety depends on the magnitude of the three-dimensional deformation,which is often judged by the displacement in each direction separately,without considering the coupling of different directions.This paper presents an experimental study of shear tests on copper water-stops under different tensile and settlement displacements,using a test stand that allows independent control of three directions and a total of 40 specimens in two different sizes are designed and fabricated.We examine shear deformation,its variations,and the failure modes of the specimens,and obtain a failure envelope surface in the three-dimensional displacement space.A failure criterion is derived for copper water-stops under three-dimensional displacement for judging the safety of similar water-stops.
作者 王立安 傅中志 丁强生 王永生 WANG Li’an;FU Zhongzhi;DING Qiangsheng;WANG Yongsheng(Geotechnical Engineering Department,Nanjing Hydraulic Research Institute,Nanjing 210024,China;Key Laboratory of Failure Mechanism and Safety Control Techniques of Earth-Rock Dams,Ministry of Water Resources,Nanjing 210029,China;ZhongShui BeiFang Investigation,Design&Research CO.LTD,Tianjin 300222,China)
出处 《水力发电学报》 CSCD 北大核心 2024年第5期94-102,共9页 Journal of Hydroelectric Engineering
基金 国家重点研发计划项目(2021YFC3090101) 国家自然科学基金(52222906,U21A20158)。
关键词 铜片止水 结构分缝 破坏准则 混凝土结构 copper water-stop structural joint failure criterion concrete structure
  • 相关文献

参考文献23

二级参考文献152

共引文献308

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部