期刊文献+

一种塔式光热发电站镜场集中监控系统

A Centralized Monitoring System for Mirror Field of Tower Solar Thermal Power Station
下载PDF
导出
摘要 塔式光热发电站由于镜场设备众多且分布范围较大,动辄成千上万面定日镜,单面定日镜通常有上百个非实时数据和数十个实时数据需要有效管理和监控,这对于常规的分散控制系统很难满足监控要求。提出以先进的通信技术、数据库技术和Web技术为基础,构建通信和数据管理服务器,在操作员站可通过浏览器来全局、成组和个别监控和操作设备,实时监控网络状态和有效管理设备参数等。 Due to the large number and distribution range of mirror field equipment in tower solar thermal power plants,there are often thousands of heliostats.Single sided heliostats usually have hundreds of non-real-time data and dozens of real-time data that need to be effectively managed and monitored,which is difficult for conventional decentralized control systems to meet monitoring requirements.This paper proposes to build a communication and data management server based on advanced communication technology,database technology,and Web technology.The operator station can use a browser to monitor and operate devices globally,in groups,and individually,monitor network status in real-time,and effectively manage device parameters.
作者 刘志声
出处 《工业控制计算机》 2024年第5期39-40,共2页 Industrial Control Computer
关键词 光热发电 HMI 镜场控制系统 CSP HMI SFCS
  • 相关文献

参考文献1

二级参考文献23

  • 1MANUEL ROMERO, REINER BUCK, JAMES E PACHECO. An update on solar central receiver systems, projects arid technologies [ J ]. ASME J Sol Energy Eng, 2002,124:98 - 108.
  • 2JAMES E PACHECO. Final test and evaluation results from the solar two project [R]. SAND2002 - 0120 Livermore, CA: Sandia National Laboratories, 2002.
  • 3KOLB, GREGORY. Solar power tower [ R ]. SAND: 9998 - 915, Livermore, CA : Sandia National Laboratories, 1999.
  • 4JOACHIM BENEMANN. Status report on solar trough power plants - experience, prospects and recommendations to overcome market barriers of parabolic trough collector power plant technology [ M ]. Germany: Pilkington Solar International Gubh, 1996.
  • 5YANG MINLIN, YANG XIAOXI, DING JING, et al. Performance comparisons of solar central receivers and working fluids for solar power tower systems (CD - ROM)//Proceedings of the 3rd International Green Energy Conference [ C ]. Vasteras Sweden: Swedish Energy Agency,2007 : 362 - 369.
  • 6KOLB GREGORY J, ALPERT DANIEL J, LOPEZ CHARLES W. Lopez. Insights from the operation of solar one and their implications for future central receiver plants[J]. Solar Energy, 1991,47( 1 ) : 39-47.
  • 7BAKER A F, FAASL S E, RADOSEVICH L G. U.S. - Spain evaluation of the solar one and CESA - 1 receiver and storage systems[ R ]. SAND88 - 8262 UC - 235, Livermore, CA: Sandia National Laboratories, 1988.
  • 8OSUNA R, FERNANDEZ V, ROMERO M, et al. 2000PS10: A 10 MW solar tower power plant for southern spain//Proc 10th Solar Paces hat [ C ]. Symposium ' Solar Thermal 2000', Sydney, Australia: 2000.13 - 18.
  • 9MICHAEL GEYER,RICHTER C, ROMERO M,et al. Solar power and chemical energy systems [ R J. Solar Paces Annual Report 2003.Koln Gemany:Tne International Energy Agency,2003.
  • 10OSUNA R, FERNANDEZ V, ROMEROS.PS10:A 11.0 MWe Solar tower power plant with saturated steam receiver (CD - ROM)//12th Solar Paces International Symposium[ C ]. Oaxaca Mexico, 2004.