期刊文献+

建筑外窗渗漏原因分析及新型外窗止水钢板的应用研究

Leakage Reason Analysis of External Windows of Buildings and Application Research of New Type External Window Water Sealing Steel Plate
下载PDF
导出
摘要 通过对北京望京地区某高端住宅楼二期工程的外窗渗漏情况进行分析,指出主框与副框之间封堵不严密是主要渗漏原因。为此,在三期工程中创新性地采用了“L”形镀锌止水钢板的新型防水构造,并对其技术原理、研究过程、施工工艺及操作要点进行了详细阐述。经过近3年的应用,该构造显著减少了渗漏问题,提升了建筑质量。 Through analyzing the leakage situation of the exterior windows of the phase 2 project of a high-end residential building in Wangjing area,Beijing,it is pointed out that the main reason for the leakage is inadequate sealing between the main frame and the sub-frame.To this end,a new waterproofing structure of L-shaped galvanized water sealing steel plate is innovatively adopted in the third phase of the project,and its technical principles,research process,construction technology and operating points are elaborated in detail.After nearly 3 years of application,this structure has significantly reduced leakage problems and improved building quality.
作者 卢浩 Lu Hao(Beijing Urban Construction Yatai Group Co.,Ltd.,Beijing 100013,China)
出处 《中国建筑防水》 2024年第11期54-58,共5页 China Building Waterproofing
关键词 建筑外窗 渗漏原因 “L”形镀锌止水钢板 防水构造 施工工艺 质量控制 住宅工程 exterior windows of buildings leakage reasons L-shaped galvanized waterproofing steel plate waterproofing structure construction technology quality control residential project
  • 相关文献

参考文献4

二级参考文献2

共引文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部