北方某市机场航站楼公共场所健康危害因素分析 被引量:4

Health hazard factors in public places of an airport terminal building in a city in northern China
原文传递
导出
摘要 目的了解北方某市机场航站楼公共场所空气卫生状况及其健康危害因素。方法按照《公共场所卫生检验方法》(GB/T 18204—2013/2014)要求进行现场采样监测或实验室检测,依据《公共场所卫生标准》(GB 9664—9672—1996及GB16153—1996)、《室内空气质量标准》(GB/T 18883—2002)和《公共场所集中空调通风系统卫生规范》(WS 394—2012)对检测结果进行评价。结果机场航站楼不同类型公共场所空气中一氧化碳、甲醛、可吸入颗粒物(PM10)、细菌总数、氨、臭氧、苯及苯系物浓度、风速、照度均符合规定要求,但温度、相对湿度、噪声、二氧化碳浓度存在不同程度的不达标现象。机场咖啡店空气二氧化碳、甲醛和细菌总数明显高于其他类型场所。航站楼集中空调通风系统中空调风管内表面积尘量,送风中PM10、细菌总数及真菌总数均存在不同程度的超标。结论该市机场航站楼内不同类型公共场所存在一些潜在的健康危害因素,主要为噪声、二氧化碳超标和集中空调通风系统卫生学指标不达标。 Objective To understand the air quality in public places of airport terminal building in a city of northern China.Methods The sampling and monitoring or laboratory testing was carried out according to Examination Methods for Public Places(GB/T 18204-2013/2014)and the results were evaluated according to hygienic standards for public places(GB 9664-9672-1996,GB 16153-1996),Indoor Air Quality Standards(GB/T 18883-2002)and Hygienic Specification of Central Airconditioning Ventilation System in Public Buildings(WS 394-2012).Results The concentration of carbon monoxide,formaldehyde,inhalable particulate matter(PM10),total bacterial count,ammonia,ozone,benzene and benzene series in the air,wind speed and illumination all met the prescribed requirements in different types of public places of airport terminal,but temperature,relative humidity,noise and the concentration of carbon dioxide exceeded the standard at different degrees.The concentrations of carbon dioxide and formaldehyde and the total number of bacteria in the air of airport coffee shops were higher than those in other types of public places.In the central air-conditioning ventilation system of the terminal building,the amount of dust in the internal surface of vatilating ducts,PM10,the total number of bacteria and fungi in supplied air exceeded the standards at different levels.Conclusion Some potential health hazard factors,such as noise,carbon dioxide and hygienic indexes for central air-conditioning ventilation system,are found in the public places of the investigated airport terminal.
作者 刘晓秋 郑晶 刘芳 张媛媛 杨少威 唐剑辉 LIU Xiao-qiu;ZHENG Jing;LIU Fang;ZHANG Yuan-yuan;YANG Shao-wei;TANG Jian-hui(Institute of Public Health Surveillance,Heilongjiang Provincial Center for Disease Control and Prevention,Harbin,Heilongjiang 150030,China)
出处 《环境与健康杂志》 CAS 北大核心 2019年第4期355-358,共4页 Journal of Environment and Health
基金 黑龙江省卫生计生委科研课题(2018-552)
关键词 机场航站楼 公共场所 健康危害因素 Airport terminal building Public places Health hazard factors
  • 相关文献

参考文献8

二级参考文献18

  • 1王慧峰,江珊毅,薛元琛,杨庆,陈昀.飞机航行中客舱内空气质量监测报告[J].中国国境卫生检疫杂志,2002,25(2):102-103. 被引量:14
  • 2苗魁,林元,冯林,赵鹏.青岛港国际航行客轮微小气候卫生质量调查[J].中国国境卫生检疫杂志,2004,27(4):234-237. 被引量:12
  • 3[1]GBZ 1-2002,工业企业设计卫生标准[S].
  • 4[2]GB 9664-1996,文化娱乐场所卫生标准[S].
  • 5[3]GB 9670-1996,商场(店)、书店卫生标准[S].
  • 6[1]GB 9672-1996,公共交通等候室卫生标准[S].
  • 7[5]GB 16153-1996,饭馆、餐厅卫生标准[S].
  • 8中华人民共和国标准.公共交通等候室卫生标准[S].GB9672-1996.
  • 9中华人民共和国标准.公共场所卫生监测技术规范[S].GB17220-1998.
  • 10金银龙.集中空调污染与健康危害控制.北京:中国标准出版社,2006:6.

共引文献11

同被引文献33

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部