摘要
提出了大型电站双背压凝汽器优化运行最佳背压的确定方法 ,并给出了计算模型。结合某台6 0 0MW汽轮机组优化试验数据 ,计算得出了双背压凝汽器的最佳背压和循环水泵最佳运行方式。将该结果应用于现场 ,取得了较好的效果。
Determination method of optimal back-pressure for optimizing operation of double back-pressure condensers in large-scale power plants has been put forward, and computation model being given. Combined with data obtained from the optimization test of a 600MW steam turbine, optimal back-pressure of the double back-pressure condenser and the optimal operation mode of circulating water pumps are achieved from said computation. These results have been used in the field, obtaining better effectiveness.
出处
《热力发电》
CAS
北大核心
2003年第3期8-11,共4页
Thermal Power Generation