^(32)P液体球囊在血管内吸收剂量的研究

Study of the endovascular absorbed dose in liquid balloon catheter filled with ^(32)P
下载PDF
导出
摘要 目的 研究32 P球囊在血管内的剂量分布。方法 用肌肉等效材料代替血管壁 ,采用热释光剂量学方法模拟测量靶血管轴向和径向吸收剂量率分布 ,并对相关影响因素 (球囊内压力 ,气泡 )进行了研究。结果  3 0mm× 2 0mm 32 P球囊 ,活度为 92MBq时 ,血管表面平均吸收剂量率为0 48Gy min ,在径向 0 4mm处为 0 2 2Gy min。结论 血管壁表面剂量分布较均匀 ,径向剂量随距离迅速衰减 ,但存在诸多影响因素。 Objective To study dose distribution of 32 P liquid balloon in experim ental intravascular brachytherapy. Methods The vessel wall was substituted by muscle equivalent material. Determination o f the dose distribution of axial and radial target vessel wall was performed by thermoluminescence dosimeters. Besides, the influencing factors such as intra- balloon pre ssure and air bubble were also studied. Results In 3.0 mm×20 mm 32 P liquid balloon with radioactivity 92 MBq, th e dose rate in balloon surface is 0.48 Gy/min, whereas in radial 0.4 mm area is 0.22 Gy/min. Conclusions The dose distribution of vessel wall su rface is uniform but the radial dose attenuated rapidly with distance. Ther e are several influencing factors existed.
出处 《中华核医学杂志》 CAS CSCD 北大核心 2003年第5期310-311,共2页 Chinese Journal of Nuclear Medicine
基金 国家自然科学基金资助项目 ( 30 1 70 2 33)
关键词 ^32P液体球囊 血管内吸收剂量 近距离放射疗法 影响因素 Blood vessels Brachytherapy Radiation dosage Model s Phosphorus radioisotopes
  • 相关文献

参考文献7

  • 1苑淑渝,孙福印.肿瘤等效材料的研制及模拟实验[J].中国辐射卫生,2000,9(2):70-71. 被引量:7
  • 2苑淑渝,孙福印.模拟测定^(32)P液体球囊血管内照射剂量[J].中国辐射卫生,2002,11(1):20-21. 被引量:5
  • 3李士骏主编.电离辐射剂量学:第2版[M].北京:原子能出版社,1985.85.
  • 4Atix FH, ed. Luminescence dosimetry,Proceedings of International Conference on Luminescence Dosimetry,Stanford University,Stanford, California, 1965.380-392, 482-489.
  • 5Shi Y, Pievie k, fard A, et al. Adventitial remodeling after coronary axterial injury. Circulation, 1996, 93: 340-348.
  • 6Waksman R, Rodriguez JC, Robinson KA, et al. Effect of intravascular irradiation on cell proliferation ,apoptosis,and vascular remodeling after balloon overstretch injury of porcine coronary arteries. Circulation, 1997, 96:1944-1952.
  • 7Mcgoron AJ, Kassing WM, Thomas SR, et al. Intravascular irradiation using ^186 Re liquid-filled balloon catheters: correlation between experimental and theoretical studies. Cadiovasc Radiat Med, 1999,1:368-375.

二级参考文献9

  • 1罗南星.测量误差及数据处理[M].计量出版社,1984..
  • 2Roger W.Howell and Dandamudi V.Rao. Macroscopic dosimetry for radioimmunotherapy nonuniform activity distributions in solid tumors[].Medical Physics.1989
  • 3Roger.Howell, Venkat R.Narra, and Dandamudi V. Rao. Absorbed dose calculations for rapidly growing tumors〔J〕[].The Journal of nuclear.1992
  • 4Barry L.Werner, Cheuk S.Kwork, Indea J. Das. Dose distribution in regions containing beta sources: large spherical source regions in a homogeneous medium〔J〕[].Medical Physics.1988
  • 5Max H. Griffith,et al.Direct dose confirmation of quantitative autoradiography with micro - TLD measurements for radioimmunotherapy〔J〕[].The Journal of Nuclear Medicine.1988
  • 6Richard B. et al.Treatment of cancer with intratumoral infusion of radioisotopes〔J〕.Int. J. Radion. Oncol. Bsol[].Physica.1994
  • 7Order S. E. et al.A new method for delivering radioactive cytotoxic agents in solid cancer〔J〕.Int. J. Radiot. Oncol[].Biol Phys.1994
  • 8霍勇,王日胜,陈明,刘兆平,朱国英.^(32)P液体球囊血管内照射预防血管介入治疗后再狭窄的实验研究[J].中华心血管病杂志,1998,26(6):436-437. 被引量:9
  • 9苑淑渝,孙福印.肿瘤等效材料的研制及模拟实验[J].中国辐射卫生,2000,9(2):70-71. 被引量:7

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部