摘要
作者首次提出了准均匀加感方法,并建立了相应的理论。同时,研制了性能优良经济实用的加感装置,在铁道电气化区段已敷设的非电化电缆上进行了现场试验,效果良好,其屏蔽效应优于电化电缆。
The paper, for the first time, proposes a method of quasiuniform pupinization and sets up its corresponding theory. Economical and practical pupinization devices with good performance have been developed. Field experiment has been made on cables without steel shield along electric railways. The shield effect of this method is better than that of the steel-sheild.
出处
《铁道学报》
EI
CAS
CSCD
北大核心
1990年第2期19-25,共7页
Journal of the China Railway Society