期刊文献+

Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10

Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture
下载PDF
导出
摘要 Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications.
出处 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页 亚太热带医药杂志(英文版)
基金 It is supported by Scientific Research Planned Project of Taizhou Science and Technology Bureau in Zhejiang:No.031212
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP Internal fixation ANKLE function Achilles tendon rupture Steel–wire limited loop Internal fixation Ankle function
  • 相关文献

参考文献16

  • 1Angelo Del Buono,Otto Chan,Nicola Maffulli.Achilles tendon: functional anatomy and novel emerging models of imaging classification[J]. International Orthopaedics . 2013 (4)
  • 2Avadhanam Pavan Kumar,Raviprakash Shashikiran,Choulapalle Raghuram.A novel modification of Bosworth’s technique to repair zone I Achilles tendon ruptures[J]. Journal of Orthopaedics and Traumatology . 2013 (1)
  • 3K.S. Wolff,A.G. Wibmer,H. Binder,T. Grissmann,K. Heinrich,S. Schauer,R. Nepp,S. Rois,H. Ritschl,H. Teufelsbauer,M.L. Pretterklieber.The avascular plane of the Achilles tendon: A quantitative anatomic and angiographic approach and a base for a possible new treatment option after rupture[J]. European Journal of Radiology . 2011 (6)
  • 4C. Tudisco,S. Bisicchia.Reconstruction of neglected traumatic Achilles tendon rupture in a young girl[J]. Journal of Orthopaedics and Traumatology . 2012 (3)
  • 5A. Gigante,A. Moschini,A. Verdenelli,M. Torto,S. Ulisse,L. Palma.Open versus percutaneous repair in the treatment of acute Achilles tendon rupture: a randomized prospective study[J]. Knee Surgery, Sports Traumatology, Arthroscopy . 2008 (2)
  • 6Tomas Movin,?sa Ryberg,Donald J. McBride,Nicola Maffulli.Acute Rupture of the Achilles Tendon[J]. Foot and Ankle Clinics of North America . 2005 (2)
  • 7Hamish D.H. Leslie,W.H.B. Edwards.Neglected Ruptures of the Achilles Tendon[J]. Foot and Ankle Clinics of North America . 2005 (2)
  • 8Chiodo Christopher P,Wilson Michael G.Current concepts review: acute ruptures of the achilles tendon. Foot & ankle international / American Orthopaedic Foot and Ankle Society [and] Swiss Foot and Ankle Society . 2006
  • 9Sanders R,Fortin P,Dipasquale T,et al.Operative treatment in 120 displaced intraarticular calcaneal fracture: results using aprognostic tomography scan classification. Clinical Orthopaedics . 1993
  • 10Gabel S,Manoli A.Neglected rupture of the Achilles tendon. Foot & ankle international / American Orthopaedic Foot and Ankle Society [and] Swiss Foot and Ankle Society . 1994

同被引文献85

引证文献10

二级引证文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部