Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry 被引量:3

Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry
下载PDF
导出
摘要 AIM: To evaluate the repeatability of central corneal thickness (CCT) measurement by entacam, and agreement of CCT measured by Pentacam and ultrasound pachymetry (USP) in Chinese myopia. Thereby investigate the possibility of Pentacam as a substitute for USP in CCT measurement before refractive surgery. The effects of corneal curvature measured by Pentacam on CCT were also evaluated. METHODS: One hundred and forty-eight right eyes of 148 individual with myopia were included in this study. Three successive Pentacam CCT measurements followed by 10 successive ultrasound pachymetry were carried out in the 148 eyes. Mean of CCT taken by each device was calculated for comparison. According to the CCT measured by USP, all the 148 eyes were divided into 3 groups: <520 mu m, 520-560 mu m, >560 mu m. For all eyes and each group the CCT obtained by Pentacam and USP were compared. Anterior corneal curvature of the 148 eyes was also adopted for correlation analysis with CCT obtained by ultrasound pachymetry. In addition, CCT measurement using 60 random selected Scheimpflug images was performed by 3 skilled investigators at different time, and this was repeated for 3 times by a forth investigator to assess repeatability of Pentacam CCT measurement using Scheimpflug images. RESULTS: Intraclass correlation coefficient (ICC) analysis revealed high intraobserver repeatability (ICC=0.994, F=158.60, P<0.001) for CCT measurement by Pentacam. The interobserver (ICC=0.998, F =494.73, P <0.001) and intraobserver (ICC=0.997, F=383.98, P<0.001) repeatability for Pentacam CCT measurements using Scheimpflug images were also excellent. There was high positive correlation between the CCT values measured by Pentacam and ultrasound pachymetry (r=0.963, P<0.001). Bland-altman plots showed that the Pentacam underestimate the CCT by 8.02 mu m compared with ultrasouond pachymetry.The differences between Pentacam and USP increased as the CCT readings by USP increased (Pentacam vs USP: slope=-0.04, P< 0.05). The 95% upper and lower limits of agreement between CCT values obtained from the two devices were +9. 33 mu m and -25.37 mu m. No significant association could be found between CCT and anterior corneal curvature. CONCLUSION: Inter- and intraobserver variability for CCT measurements by Pentacam was considerably below clinically significant levels. CCT of myopia obtained by Scheimpflug camera, Pentacam, were highly correlated to that by ultrasound pachymetry. However, the values obtained are not directly interchangeable between Pentacam and ultrasound pachymetry as the 95% limits of agreement are relatively wide. Pentacam can be a useful instrument for measuring CCT in candidates to refractive surgery in clinic. AIM: To evaluate the repeatability of central corneal thickness (CCT) measurement by entacam, and agreement of CCT measured by Pentacam and ultrasound pachymetry (USP) in Chinese myopia. Thereby investigate the possibility of Pentacam as a substitute for USP in CCT measurement before refractive surgery. The effects of corneal curvature measured by Pentacam on CCT were also evaluated. METHODS: One hundred and forty-eight right eyes of 148 individual with myopia were included in this study. Three successive Pentacam CCT measurements followed by 10 successive ultrasound pachymetry were carried out in the 148 eyes. Mean of CCT taken by each device was calculated for comparison. According to the CCT measured by USP, all the 148 eyes were divided into 3 groups: <520 mu m, 520-560 mu m, >560 mu m. For all eyes and each group the CCT obtained by Pentacam and USP were compared. Anterior corneal curvature of the 148 eyes was also adopted for correlation analysis with CCT obtained by ultrasound pachymetry. In addition, CCT measurement using 60 random selected Scheimpflug images was performed by 3 skilled investigators at different time, and this was repeated for 3 times by a forth investigator to assess repeatability of Pentacam CCT measurement using Scheimpflug images. RESULTS: Intraclass correlation coefficient (ICC) analysis revealed high intraobserver repeatability (ICC=0.994, F=158.60, P<0.001) for CCT measurement by Pentacam. The interobserver (ICC=0.998, F =494.73, P <0.001) and intraobserver (ICC=0.997, F=383.98, P<0.001) repeatability for Pentacam CCT measurements using Scheimpflug images were also excellent. There was high positive correlation between the CCT values measured by Pentacam and ultrasound pachymetry (r=0.963, P<0.001). Bland-altman plots showed that the Pentacam underestimate the CCT by 8.02 mu m compared with ultrasouond pachymetry.The differences between Pentacam and USP increased as the CCT readings by USP increased (Pentacam vs USP: slope=-0.04, P< 0.05). The 95% upper and lower limits of agreement between CCT values obtained from the two devices were +9. 33 mu m and -25.37 mu m. No significant association could be found between CCT and anterior corneal curvature. CONCLUSION: Inter- and intraobserver variability for CCT measurements by Pentacam was considerably below clinically significant levels. CCT of myopia obtained by Scheimpflug camera, Pentacam, were highly correlated to that by ultrasound pachymetry. However, the values obtained are not directly interchangeable between Pentacam and ultrasound pachymetry as the 95% limits of agreement are relatively wide. Pentacam can be a useful instrument for measuring CCT in candidates to refractive surgery in clinic.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期329-333,共5页 国际眼科杂志(英文版)
关键词 PENTACAM central corneal thickness ultrasound pachymetry REPEATABILITY AGREEMENT pentacam central corneal thickness ultrasound pachymetry repeatability agreement
  • 相关文献

参考文献11

  • 1Hani S. Al-Mezaine,Saleh A. Al-Amro,Dustan Kangave,Abdulkareem Sadaawy,Taher A. Wehaib,Saleh Al-Obeidan.Comparison between central corneal thickness measurements by oculus pentacam and ultrasonic pachymetry[J].International Ophthalmology.2008(5)
  • 2Ciolino J B,Khachikian S S,Belin M W.Comparison of corneal thickness measurements by ultrasound and scheimpflug photography in eyes that have undergone laser in situ keratomileusis[].American Journal of Ophthalmology.2008
  • 3De Sanctis U,Missolungi A,Mutani B,et al.Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry[].American Journal of Ophthalmology.2007
  • 4Swartz T,Marten L,Wang M.Measuring the cornea:the latestdevelopments in corneal topography[].Current Opinion in Ophthalmology.2007
  • 5M. Fujioka,M. Nakamura,Y. Tatsumi,A. Kusuhara,H. Maeda,A. Negi.Comparison of Pentacam Scheimpflug camera with ultrasound pachymetry and noncontact specular microscopy in measuring central corneal thickness[].Current Eye Research.2007
  • 6C O’Donnell,C Maldonado-Codina.Agreement and repeatability of central thickness measurement in normal corneas using ultrasound pachymetry and the Oculus Pentacam[].Cornea.2005
  • 7Ucakhan OO,Ozkan M,Kanpolat A.Corneal thickness measurements in normal and keratoconic eyes:Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry[].Journal of Cataract and Refractive Surgery.2006
  • 8Ho T,Cheng AC,Rao SK,et al.Central corneal thickness measurements using Orbscan II,Visante,ultrasound and Pentacam pachymetry after laserin situ keratomileusis for myopia[].Journal of Cataract and Refractive Surgery.2007
  • 9Doughty MJ,Zaman ML.Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach[].Survey of Ophthalmology.2000
  • 10Heijl A,Leske MC,Bengtsson B,et al.Reduction of intraocular pressure and glaucoma progression: results from the early manifest glaucoma trial[].Archives of Ophthalmology.2002

同被引文献15

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部