期刊文献+

评估功能性电刺激治疗截瘫患者行走效率的三维重心动态图 被引量:7

3-D center of gravity mapping:a new method for assessment of FES-assisted paraplegic walking efficiency
原文传递
导出
摘要 目的 研究功能性电刺激 (functionalelectricalstimulation ,FES)治疗截瘫患者行走效率的评估方法。方法 介绍一种用三维重心动态图来评估FES治疗截瘫患者行走效率的新方法。其主要构件是一套基于标准步行器的测试系统 ,该系统可以实时获得上肢支撑力数据 ,通过一套截瘫上躯干力学模型转化为三维重心动态图来显示重心运动轨迹 ,从而客观定量地评估出用身体平衡状况表征的FES行走效率。结果 静态标定显示系统测试精确度好于 1.0 1% ,非线性度小于 0 .8% ,交互干扰小于 3 .2 %。相关测试结果来自正在接受FES行走训练的截瘫患者。结论 初步表明该方法可以用于 :(1)FES治疗截瘫患者行走效率的评估 ;(2 )患者自我训练的平衡控制指导 ;(3 )作为反馈信号选择一种有效的FES模式和阵列 。 Objective To explore a new method for assessing the walking efficiency of the paraplegic patients assisted by functional electrical stimulation (FES). Methods The measurement system based on a standard walker was developed. During FES assisted walking of the paraplegic, the real time of the upper limb support were obtained and transformed into a 3 D center of gravity (CG) motion map with a paraplegic upper body mechanical model to describe the CG motion locus. Then the FES efficiency indicated by walking balance condition was assessed objectively and quantitatively. Results In this design, the pilot study of a paraplegic patient undergoing walking training with FES showed that the force accuracy was better than 1.01%, nonlinearity was less than 0.8%, and crosstalk was less than 3.2%. Conclusion The results showed that this system may be used as 1) an evaluation index of FES assisted paraplegic walking efficiency, 2) a balance control indicator during FES assisted paraplegic walking training and 3) a feed back signal to choose an efficient FES pattern and sequence.
出处 《中华物理医学与康复杂志》 CAS CSCD 北大核心 2004年第8期466-471,共6页 Chinese Journal of Physical Medicine and Rehabilitation
关键词 功能性电刺激 FES 截瘫 行走效率 三维重心动态图 上躯干力学模型 辅助装置 Functional electrical stimulation Paraplegic 3-D CG motion map Walker Upper body mechanical model
  • 相关文献

参考文献10

  • 1The National SCI Statistical Center. Facts and figures at a glance. Birmingham: University of Alabama, 1999.1-3.
  • 2Phillips WT, Kiratli B J, Sarkarati M, et al. Effect of spinal cord injury on the heart and cardiovascular fitness. Curr Probl Cardiol, 1998,23:641-716.
  • 3Fall M. Advantages and pitfalls of functional electrical stimulation. Acta Obstet Gynecol Scand Suppl, 1998,168:16-21.
  • 4Popovic MR, Curt A, Keller T, et al. Functional electrical stimulation for grasping and walking: indications and limitations. Spinal Cord,2001, 39:403-412.
  • 5Karcnik T, Kralj A. Stability and energy criteria in healthy and paraplegic subject gait. Artif Organs, 1997, 21:191-194.
  • 6Agarwal S, Kobetic R, et al. Functional electrical stimulation for walking in paraplegia: 17-year follow-up of 2 cases. J Spinal Cord Med,2003, 26:86-91.
  • 7Gfohler M, Angeli T, Eberharter T, et al. Test bed with force-measuring crank for static and dynamic investigations on cycling by means of functional electrical stimulation. IEEE Trans Neural Syst Rehabil Eng,2001, 9:169-180.
  • 8Gfohler M, Angeli T. Functional electrical stimulation for walking in paraplegia: 17-year follow-up of 2 cases. J Spinal Cord Med, 2003,26:86-91.
  • 9Gillette JC, Quick NE, Abbas JJ. Center of pressure measures to assess standing performance. Biomed Sci Instrum, 2002, 38: 239-244.
  • 10张光铂.我国脊柱脊髓损伤基础研究、临床、康复的现状与展望[J].中国康复医学杂志,2002,17(4):201-202. 被引量:26