针对当前氯碱行业高速发展,大量使用离子膜复极槽的现状,对同相逆并联在整流装置中的应用进行了讨论。认为在直流电压为300~450V,直流电流≤15kA时,采用同相逆并联技术并非最佳选择。
According to the high development of chlor-alkali industry and the using present of bipo-lar type ion-exchange membrane electrolyzer, the application of the process on cophase counter parallel connection in rectifying units were discussed. It considered that the process on cophase counter parallel connection was not the best selection when the voltage of direct current was 300~450 V, and the current quantity of direct current was less than or equal to 15 kA.
出处
《中国氯碱》
CAS
2005年第3期4-7,30,共5页
China Chlor-Alkali
关键词
整流装置
并联
直流电压
直流电流
高速
复极槽
离子膜
氯碱行业
bipolar type ion-exchange membrane electrolyzer
parameter of rectifier cophase counter parallel connection