摘要 介绍了一种基于振荡波理论的振荡波电压测试系统及其国内外研究现状;讨论了该测试系统在电力电缆的耐压试验、局部放电检测中的应用。研究表明,振荡波电压与交流电压具有良好的等效性,且与交流电压、超低频电压(0.1 Hz)相比,作用时间短、操作方便,可发现XLPE电力电缆中的各种缺陷,不会对电缆造成损伤,因此振荡波电压测试系统具有良好的应用前景。 Along with the wide use of XLPE power cable in the electrical power system, its test engineering and test method have been becoming more and more important. The paper introduces a kind of oscillatory wave voltage test system based up on oscillatory wave theory and its research status at home and abroad, discusses its application in the withstand voltage test and partial discharge detection of power cables. It is proved that oscillatory wave voltage have good equivalence with alternating voltage, and compared with alternating voltage and very low frequency voltage (0. 1 Hz), it has some advantages such as shorter operating time and easier operation and so on. It can find most kinds of defects in XLPE power cable effectively, and dose no harm to the cable, so it has a good future.
出处 《高电压技术》 EI CAS CSCD 北大核心 2006年第3期27-30,共4页 High Voltage Engineering
关键词 振荡波电压 XLPE电力电缆 耐压试验 局部放电 oscillating wave voltage XLPE power cable withstand voltage test partial discharge
  • 相关文献

参考文献17

  • 1饶强.交联聚乙烯电缆新的试验方法[J].广西电业,2004(8):107-109. 被引量:8
  • 2Schalk N van.On-site testing of high voltage systems after laying:voltage test[C].IEEE Colloquium On Super Tension (66-500 kV) Polymeric Cables and Their Accessories.[S.l.],1995.
  • 3罗俊华,马翠姣,邱毓昌,金祎,陈守直,史济康.35kV及以下XLPE电力电缆试验方法的研究[J].电网技术,2000,24(12):58-61. 被引量:62
  • 4张平康,韩伯锋.XLPE电缆的试验方法[J].高电压技术,2004,30(z1):94-95. 被引量:23
  • 5Boyego K,Hyvonen P,Martti Aro,et al.Selectivity of damped ac (DAC) and VLF voltages in after-laying tests of extruded MV cable systems[J].IEEE Trans on D&EI,2003,5(10):874-882.
  • 6Uchida K,Tanaka H,Hirotsu K.Study on detection for the defects of XLPE cable lines[J].IEEE Trans on PWRD,1996.2(11):668.
  • 7Gulski E,Frank J,Johan J,et al.Advanced partial discharge diagnostic of MV power cable system using oscillating wave test system[J].IEEE Electrical Insulation Magazine,2000,2(16):17-25.
  • 8IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems[S].USA:IEEE,2002.
  • 9Koo J,Kim J,Lee J,et al.A study on the oscillating wave voltage test as an after-laying test for distribution power cables[C].IEEE Annual Report-Conference on Electrical Insulation and Dielectric Phenomena.[S.1.],1997.
  • 10罗俊华,杨黎明,史济康,朱海钢.电力电缆及试验技术回顾[J].高电压技术,2004,30(z1):81-82. 被引量:49

二级参考文献21

  • 1韦斌,王伟,李成榕,李信,李华春.VHF钳型传感器在线检测110kV XLPE电缆局放[J].高电压技术,2004,30(7):37-39. 被引量:34
  • 2罗俊华,袁淳智.XLPE电力电缆在直流电场下介质树枝状劣化特性的研究[J].高电压技术,1993,19(1):41-46. 被引量:15
  • 3[1]Working Group 21.09 After laying tests on high voltage extruded insulation cable system[J]. Electra, 1997, (173) :33-41
  • 4[3]Steven Boggs. Fundaments of partial discharge in the context of field cable testing [ J ]. IEEE Electrical Insulation Magazine. 2000,16(25): 13-18
  • 5[4]Heizmann Th. On-site partial discharge measurements on premoulded cross-bonding joints of 170kV XLPE and EPR cables [J]. IEEE Trans on Power and Delivery, 1998,13(2) : 330-335
  • 6[6]马翠姣.XLPE电力电缆局部放电试验研究[D].西安:西安交通大学硕士学位论文,2001
  • 7[7]Shim I, Sorahan J J, Siew W H. Digital signal processing applied to the detection of partial discharge: An overview[J], IEEE Electrical Insulation Magazine. 2000, 16(3):6-12
  • 8[1]Heinhold L.门汉文等译.电力电缆及电线[M].北京:中国电力出版社,2001
  • 9Ginzo Katsuta, Atsushi Toya, Keiichi Muraoka, et al. Development of a method partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines[J]. IEEE Trans on Power Delivery, 1992, 7(3): 1068-1074.
  • 10Heizmann Th, Aschwanden Th, Hahn H, et al. On-site partial discharge measurements on premoulded cross-bonding joints of 170 kV XLPE and EPR cables[J]. IEEE Trans on Power Delivery, 1998, 13(2):330-335.

共引文献145

同被引文献419

引证文献62

二级引证文献442

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部