摘要 A new absorbent of nanometer-size TiO2 colloid for Cu(Ⅱ ) was studied in this work. The adsorption rate could reach above 99% when the pH values were at the range of 5-6. The adsorption balance time, adsorption capacities, and the eluent were investigated. A novel method of trace Cu( Ⅱ ) preconcentration and separation with nanometer-size titanium dioxide colloid and determination by flame atomic absorption spectrometry (FAAS) was advanced. The detection limit (3a) of the method was 1.15 μg · L^-1, and the relative standard deviation (R.S.D) was 1.53% (n=6). Environmental sample experiments were also conducted to test the feasibility of the method, and it came out that the recovery rates were between 95.9% and 97.8%. A new absorbent of nanometer-size TiO2 colloid for Cu(Ⅱ ) was studied in this work. The adsorption rate could reach above 99% when the pH values were at the range of 5-6. The adsorption balance time, adsorption capacities, and the eluent were investigated. A novel method of trace Cu( Ⅱ ) preconcentration and separation with nanometer-size titanium dioxide colloid and determination by flame atomic absorption spectrometry (FAAS) was advanced. The detection limit (3a) of the method was 1.15 μg · L^-1, and the relative standard deviation (R.S.D) was 1.53% (n=6). Environmental sample experiments were also conducted to test the feasibility of the method, and it came out that the recovery rates were between 95.9% and 97.8%.
出处 《Wuhan University Journal of Natural Sciences》 CAS 2007年第2期349-352,共4页 武汉大学学报(自然科学英文版)
基金 Supported by the Natural Science Foundation of Hubei Province(2006ABA236)
关键词 Cu( nanometer-size TiO2 colloid preconcentra-tion flame atomic absorption spectrometry (FAAS) Cu( Ⅱ ) nanometer-size TiO2 colloid preconcentra-tion flame atomic absorption spectrometry (FAAS)
  • 相关文献

参考文献9

  • 1Shunxing Li,Nansheng Deng.Separation and preconcentration of Se(IV)/Se(VI) species by selective adsorption onto nanometer-sized titanium dioxide and determination by graphite furnace atomic absorption spectrometry[J].Analytical and Bioanalytical Chemistry (-).2002(7-8)
  • 2Li Shunxing,Deng Nansheng,Zheng Fengying,et al.Spec- trophotometric Determination of Tungsten(Ⅵ) Enriched by Nanometer-Size Titanium Dioxide in Eater and Sediment[].Talanta.2003
  • 3Mendiguchia C,Moreno C,Garcia M.Determination of Copper in Seawater Based on a Liquid Membrane Precon- centration System[].Analytica Chimica Acta.2002
  • 4Lemos V A,Baliza P X,Yamaki R T,et al.Synthesis and Application of a Functionalized Resin in on-Line System for Copper Preconcentration and Determination in Foods by Flame Atomic Absorption Spectrometry[].Talanta.2003
  • 5Liang Pei,Shi Taqing,Lu Hanbing,et al.Speciation of Cr(Ⅲ) and Cr(Ⅵ) by Nanometer Titanium Dioxide Mi- cro-Column and Inductively Coupled Plasma Atomic Emis- sion Spectrometry[].Spectrochimica Acta.2003
  • 6Liang Pei,Qin Yongchao,Hu Bin,et al.Nanometer-Size Titanium Dioxide Microcolumn on-Line Preconcentration of Trace Metals and Their Determination by Inductively Cou- pled Plasma Atomic Emission Spectrometry in Water[].Analytica Chimica Acta.2001
  • 7Zsfia S,Istvn B,Klra T,et al.A Novel Polymeric MembraneElectrode for the Potentiometric Analysis of Cu(Ⅱ) in Drinking Water[].Analytica Chimica Acta.2005
  • 8Beppu M M,Arruda E J,Vieira R S,et al.Adsorption of Cu(Ⅱ) on Porous Chitosan Membranes Functionalized with Histidine[].Journal of Membrane Science.2004
  • 9Vassileva E,Proinova I,Hadjiivanov K.Solid-Phase Extrac- tion of Heavy Metal Ions on a High Surface Area Titanium Dioxide (Anatase)[].The Analyst.1996

同被引文献62

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部