期刊文献+

Plasma Density Measurements in Cable Gun Experiments with a Sensitive He-Ne Interferometer

Plasma Density Measurements in Cable Gun Experiments with a Sensitive He-Ne Interferometer
下载PDF
导出
摘要 A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun. A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第3期292-295,共4页 等离子体科学和技术(英文版)
关键词 plasma opening switch INTERFEROMETER plasma density cable plasma gun plasma opening switch, interferometer, plasma density, cable plasma gun
  • 相关文献

参考文献7

  • 1Dolgachev G I, Ushakov A G. 2001, Plasma Physics Reports, 27:110
  • 2Weber B V, Hinshelwood D D, Commisso R J, et al. 1997, IEEE Trans. on Plasma Science, 25:189
  • 3Lisitsyn I V, Kohno S, Kawauchi T, et al. 1997, Jpn. J. Appl. Phys., 36:6986
  • 4Weber B V, Fulghum S F. 1997, Rev. Sci. Instrum, 68: 1227
  • 5Mason R J. 1992, ANTHEM simulational studies of the plasma opening switch. Beams 92: 9th Int. Conf. on High-Power Particle Beams, Washington. p.547
  • 6Jiang Wei, Chen Lin, He An, et al. 2005, Chinese Journal of Lasers, 32:1286 (in Chinese)
  • 7Kohno S, Teramoto Y, Lisitsyn I V, et al. 1999, IEEE trans.on Plasma Science, 27:778

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部