期刊文献+

两种新型太阳能通风窗在香港地区的实验研究 被引量:10

EXPERIMENTAL STUDY OF TWO NOVEL VENTILATED SOLAR SCREEN WINDOWS IN HONG KONG
下载PDF
导出
摘要 介绍了两种新型太阳能通风窗的原理和结构,以已有的控温热箱为基础,建立了太阳能通风窗实验平台,在亚热带气候条件下,对普通单层窗、自然通风双层窗、强迫通风双层窗进行了对比实验研究。结果显示,相对于普通单层窗,在基本满足室内采光要求的前提下,自然通风双层窗可以减少室内得热的38%;强迫通风双层窗可以减少室内得热的62%,明显降低了空调系统的冷负荷和能源消耗。 Two novel ventilated solar screen windows were introduced and an experimental rig has been set up based on a temperature-controlled building hot box in Hong Kong, a subtropical city. The contrastive experimental study of single glazing window, nature ventilated double glazing window and force ventilated double glazing window has been done. Experimental results showed that the nature ventilated double glazing and force ventilated double glazing window can reduce the indoor heat gain through the window 38 % and 63 % of single glazing window, respectively. Under the condition of fulfilling indoor lighting standard by using of daylight, the energy consumed by air-conditioner is reduced evidently.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2009年第3期282-286,共5页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(50478023) 安徽省自然科学基金(070414161)
关键词 太阳能 通风窗 室内得热 室内采光 solar energy ventilated window indoor heat gain indoor lighting
  • 相关文献

参考文献8

  • 1Miyazaki T, Akisawa A, Kashiwagi T. Energy savings of office buildings by the use of semi-transparent solar cells for windows[J]. Renewable Energy, 2005, 30:281-304.
  • 2Tanimoto J, Kimura K I. Simulation study on an air flow window system with an integrated roll screen[J].Energy and Buildings, 1997, 26:317-325.
  • 3Mcevoy M E, Southall R G, Baker P H. Test cell evaluation of supply air windows to characterize their optimum performance and its verification by use of modeling techniques[J]. Energy and Buildings, 2003, 35:1009-1020.
  • 4Etzion Y, Erell E. Controlling the transmission of radiant energy through windows: a novel ventilated reversible glazing system[J]. Building and Environment, 2000, 35:433-444.
  • 5Erell E, et al. "SOLVENT" development of a reversible solar-screen glazing[J]. Energy and Buildings, 2004, 36: 467-480.
  • 6Chow T T, Lin Z, He W, et al. Use of ventilated solar screen window in warm climate[J]. Applied Thermal Engineering, 2006, 26:1910-1918.
  • 7Chow T T, Fong K F, He W, et al. Performance evaluation of a PV ventilated window applying to office building of Hong Kong[J]. Energy and Buildings, 2007, 39:643-650.
  • 8Chow T T, Chart A L S, Fong K F, et al. Hong Kong solar radiation on building facades evaluated by numerical models [J]. Applied Thermal Engineering, 2005, 25:1908-1921.

同被引文献73

引证文献10

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部