期刊文献+

Determination of Ca,K,Mg and Fe in Four Fish Species by FAAS 被引量:8

Determination of Ca,K,Mg and Fe in Four Fish Species by FAAS
下载PDF
导出
摘要 A method for determining calcium (Ca), potassium (K), magnesium (Mg) and iron (Fe) in four fish species was opti- mized and validated. It included microwave mineralization of the samples and subsequent quantification by flame atomic absorption spectroscopy (FAAS) with Zeeman-effect background correction. Using HNO3 (65%) and H202 (33%) as extraction solutions, the optimal conditions of extraction were established as follows: 0.5 g of sample mass; microwave time program of 300 W/5 min and 600 W/5 min. The method was free of matrix interferences. The linear correlation coefficients were ≥0.9991, the recovery percentage of analytes was from 99.31% to 103.70% and the RSD (relative standard deviation) was lower than 2.06%. The detection limits obtained were 32.3, 43.2, 14.0 and 68.6ng mL^-1 for Ca, K, Mg and Fe in FAAS respectively. It is shown that the method is rapid, simple, sensitive and accurate. The method was applied to the studies of digestibility and measurement of these nutrients in samples of fish collected from Norway, Japan and China. A method for determining calcium(Ca),potassium(K),magnesium(Mg) and iron(Fe) in four fish species was optimized and validated.It included microwave mineralization of the samples and subsequent quantification by flame atomic absorption spectroscopy(FAAS) with Zeeman-effect background correction.Using HNO3(65%) and H2O2(33%) as extraction solutions,the optimal conditions of extraction were established as follows:0.5 g of sample mass;microwave time program of 300 W/5 min and 600 W/5 min.The method was free of matrix interferences.The linear correlation coefficients were ≥0.9991,the recovery percentage of analytes was from 99.31% to 103.70% and the RSD(relative standard deviation) was lower than 2.06%.The detection limits obtained were 32.3,43.2,14.0 and 68.6 ng mL-1 for Ca,K,Mg and Fe in FAAS respectively.It is shown that the method is rapid,simple,sensitive and accurate.The method was applied to the studies of digestibility and measurement of these nutrients in samples of fish collected from Norway,Japan and China.
出处 《Journal of Ocean University of China》 SCIE CAS 2010年第3期235-238,共4页 中国海洋大学学报(英文版)
关键词 flame atomic absorption spectrometry (FAAS) FISH CALCIUM MAGNESIUM POTASSIUM IRON microwave digestion 火焰原子吸收法 火焰原子吸收光谱法 鱼类 线性相关系数
  • 相关文献

参考文献6

二级参考文献31

共引文献47

同被引文献61

引证文献8

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部