摘要
应用以葡萄球菌A蛋白协同凝集试验(SPA-COA)为主要检测手段的鱼病诊断箱,于1995~1997年在吉林、辽宁等7省进行现场检测试验。结果,61个渔场11个品种的516尾病鱼有菌生长的为285尾,经SPA-COA鉴定阳性数为239尾,占有菌生长的83.86%;12个渔场5个品种1216尾假定健康鱼有菌生长的为28尾,经SPA-COA鉴定阳性数为22尾,占有菌生长的78.57%。认为本诊断箱适用于基层渔场。能用SPA-COA法鉴定16株病原菌等工作。
A kit for detecting 16 strains of pathogenic bacteria that cause fish diseases mainly by SPA coagglutination assay(SPA-COA)were clinically applied within 7 provinces in china from 1995 to 1997.The results demonstrated that 285 of 516 diseased fish from 11 species in 61 fish farms carryed bacteria and 239 of the 285(83.86%)fishes were detected positive by the kit 28 of 1216 hypothetical healthy fishes from 5 species in 12 fish farms carryed bactreia and 22 of the 28(78.57%)fishes were detected positive by the kit.The results suggest that the kit was suitable in fish farms,can be used to pathogenic dissecting,bacteria culture or identify and fish bacteria disease diagnosis.
出处
《黑龙江畜牧兽医》
CAS
北大核心
1999年第8期4-5,共2页
Heilongjiang Animal Science And veterinary Medicine
基金
解放军总后勤部军需部研究课题
关键词
淡水鱼类
SPA-COA
鱼病诊断箱
应用试验
freshwater fishes
SPA-COA
fish diseases diagnosis kit
application practice