期刊文献+

光谱辐射计波长定标新方法的研究 被引量:1

Study of New Wavelength Calibration Way for Spectrometer
下载PDF
导出
摘要 在空间、野外等环境下光谱辐射计常常需要进行波长定标,通常的室内定标法无法满足其要求,为此,本文通过对稀土氧化物中氧化饵与氧化镝的光谱特性和稳定性的研究,认为它们非常适合作为光谱辐射计波长定标参考板的主要材料.该种参考板的研制成功将改变现有波长定标仅能在室内进行的限制,从而解决了不同环境要求波长定标的难题.本参考板也可作为室内波长定标的标准. To wavelength calibration in some enviroment, such as on satellite or in field, it is impossible using ordinary way that is used in laboratory. By studying the character of spectrum and stabilization of erbium oxide and dysprosium oxide,we conclude that it is very appropriate using them as main material of wavelength calibration panel for spectrometer. The panel will solve the problem that wavelength calibration can only be done in laboratory, at the same time, it can also provide a standard of wavelength calibation in laboratory.
出处 《量子电子学报》 CAS CSCD 1999年第5期442-447,共6页 Chinese Journal of Quantum Electronics
基金 "中国遥感卫星辐射校正场"项目
关键词 稀土氧化物 波长定标 光谱辐射计 rare-earth oxide, wavelength calibration, spectrometer
  • 相关文献

参考文献8

  • 1徐光宪 袁承业 等.稀土的溶剂萃取[M].北京:科学出版社,1991.344.
  • 2遥感研究会 刘勇卫等(译).遥感精解(日)[M].北京:测绘出版社,1993.2-6.
  • 3Biggar S F 美国亚利桑那大学光学科学中心(译).在轨卫星传感器绝对辐射定标(博士论文)[M].,1992,6..
  • 4李在清,光谱光度测量与标准,1993年,152页
  • 5刘勇卫(译),遥感精解(日),1993年,2页
  • 6国家卫星气象中心(译),博士学位论文,1992年
  • 7徐光宪,稀土的溶剂萃取,1991年,7页
  • 8张若桦,稀土元素化学,1987年,1页

共引文献6

同被引文献12

  • 1许纪霖.共和爱国主义与文化民族主义——现代中国两种民族国家认同观[J].华东师范大学学报(哲学社会科学版),2006,38(4):1-13. 被引量:51
  • 2ROBERT O G.Spectral calibration requirement for Earth-looking imaging spectrometers in the solar-reflected spectrum[J].Appl.Opt.,1998,37:683-690.
  • 3LUIS G,RUDOLF R,JOS M.Spectral calibration of hyperspectral imagery using atmospheric absorption features[J].Appl.Opt.,2006,45:2360-2370.
  • 4GAO B C,MONTES M J,DAVIS C O.Refinement of wavelength calibrations of hyperspectral imaging data using a spectrum-matching technique[J].Remote Sens.Environ.,2004,90:424-433.
  • 5LUIS G,KARL S,BERNHARD S,et al..Scene-based spectral calibration assessment of high spectral resolution imaging spectrometers[J].Opt.Express,2009,17:11594-11606.
  • 6PAMELA B,JOHN S,CAROL S.Hyperion on-orbit validation of spectral calibration using atmospheric lines and an on-board system[J].SPIE,2002,4480:231-235.
  • 7HEDMAN T R,JARECKE P J,LIAO L B.Hyperspectral imaging spectrometer spectral calibration[P].United State:6,111,640.2000-08-29.
  • 8JUNGHWAN C,PAUL J,GEMPERLINE,et al..Wavelength calibration method for a CCD detector and multichannel fiber-optic probes[J].Appl.Spectrosc,1995,49:1841-1845.
  • 9JACK J H,VICTOR R W.NBS 45°/normal reflectometer for absolute reflectance factors[J].Metrologia,1981(17):97-102.
  • 10JOHN H L.Diffuse light correction for field reflectance measurements[D].Tucson:University of Arizona,2002.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部