摘要 并行磁共振成像技术已在MRI领域被广泛应用。本研究提出一种新的并行成像方法,命名为GRAPPA-SENSE。此法应用GRAPPA(generalized autocalibrating partially parallel acquisitions)算法内插出部分K空间中心未采集数据,生成更为精确的SC-SENSE(self-calibrating sensitivity encoding)重建算法所需的线圈敏感度函数。标准水模实验证明此方法可改善图像质量。 Parallel magnetic resonance image technology has been widely used in MRI field.A novel method named as GRAPPA-SENSE was proposed in this paper.GRAPPA-SENSE was developed using generalized autocalibrating partially parallel acquisitions(GRAPPA) algorithm to intervene more missing lines in central K-space in order to generate accurate coil sensitivities for self-calibrating sensitivity encoding(SC-SENSE) algorithm.This method was tested by using experimental data of a standard water phantom,and the results demonstrated that the image quality had been improved.
作者 王达 包尚联
出处 《中国医学影像技术》 CSCD 北大核心 2011年第8期1688-1693,共6页 Chinese Journal of Medical Imaging Technology
基金 国家自然科学基金(30970772) 国家重点基础研究发展计划(973计划)项目(2011CB707701) 北京市教委共建项目(JD100010607)
关键词 GRAPPA算法 SENSE算法 线圈敏感度 GRAPPA algorithm SENSE algorithm Coil sensitivity
  • 相关文献

参考文献10

  • 1张宏杰,宋枭禹,包尚联,俎栋林.磁共振成像射频线圈技术[J].中国医学影像技术,2005,21(9):1440-1441. 被引量:24
  • 2Ohliger MA, Sodiekson DK. An introduction to coil array design for parallel MRI. NMR Biomed, 2006, 19(3) :300-315.
  • 3姚志萍,杨昆,汪建涛,任秋实.磁共振成像射频线圈的设计及仿真[J].中国医学影像技术,2006,22(9):1421-1423. 被引量:3
  • 4Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequeney coil arrays. Magn Reson Med, 1997,38(4) :591-603.
  • 5Jakob PM, Griswold MA, Edelman RR, et al. AUTO-SMASH: a self calibrating technology for SMASH imaging. MAGMA, 1998,7(1):42- 54.
  • 6Heidemann RM, Griswold MA, Haase A, et al. VD-AUTO- SMASH imaging. Magn Reson Med, 2001,45(6):1066 -1074.
  • 7Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med, 2002,47(6) :1202-1210.
  • 8Pruessmann KP, Weiger M, Scheidegger MB, et al. SENSE: sensitivity encoding for fast MRI. Magn Reson Med, 1999, 42 (5) :952-962.
  • 9McKenzie CA, Yeh EN, Ohliger MA, et al. Self-calibrating parallel imaging with automatic coil sensitivity extraction. Magn Re son Med, 2002,47(3):529- 538.
  • 10Ying L, Sheng J. Joint image reconstruction and sensitivity esti marion in SENSE (JSENSE). Magn Reson Med, 2007,57 (6) 1196-1202.

二级参考文献19

  • 1张宏杰,宋枭禹,包尚联,俎栋林.磁共振成像射频线圈技术[J].中国医学影像技术,2005,21(9):1440-1441. 被引量:24
  • 2Doty FD, Entzminger G, Yang YA. Magnetism in HR NMR probe design[J]. Concepts Magn Reson, 1998,10(4) :133 156.
  • 3Harald HQ, Mark EL, Gesine G, et al. Single-loop coil concepts for intravascular magnetic resonance imaging [J] . MRM, 1999,41 (4) :751-758.
  • 4Tropp J. The theory of the bird-cage resonator[C].In Proceedings of the 11th Annual Meeting of the Society of Magnetic Resonance in Medicine. Society for Magnetic Resonance in Medicine, 1992.
  • 5Su S, Zou MX, Murphy-Boesch J. Solenoidal array coils [J]. MRM, 2002,47(4): 794-799.
  • 6Jin JM. Electromagnetics in magnetic resonance imaging[J]. IEEE Antennas and Propagation Magazine, 1998,40( 1 ): 7-22.
  • 7Doty FD. Probe design and construction [J]. Encyclopedia of NMR, 1996,6(2): 3753-3762.
  • 8Wright SM, Wald LL. Theory and application of array coils in MR spectroscopy[J]. NMR Biomed, 1997,10(6) :394-410.
  • 9Vaughan JT, Hetherington HP. High frequency volume coils for clinical NMR imaging and spectroscopy [J] . MRM, 1994, 32 ( 2 ): 206-218.
  • 10Pearce RB. New surface coil designs enhance MRI performance[J]. Diagn Imaging, 1988,10(1): 117-129.

共引文献24

同被引文献28

  • 1康宁,俎栋林,张宏杰.自旋密度ρ、弛豫时间T1和T2定量磁共振成像[J].中国医学影像技术,2004,20(12):1944-1947. 被引量:16
  • 2夏爽,祁吉.MR并行采集技术的优势[J].国外医学(临床放射学分册),2006,29(5):348-353. 被引量:18
  • 3田俊,杨亚芳,韩晖云.MR成像伪影与消除[J].实用放射学杂志,2007,23(5):705-707. 被引量:14
  • 4康庄,卢广文,邹艳,王亮.骨关节不锈钢钉植入术后的磁共振影像技术[J].南方医科大学学报,2007,27(8):1282-1284. 被引量:2
  • 5于曰俊,张国华,侯金文.磁共振并行采集技术的临床应用[J].中国中西医结合影像学杂志,2007,5(5):366-368. 被引量:5
  • 6Haacke EM, Brown RW. Magnetic resonance imaging: Physicalprinciples and sequence design. New York: John Wiley &. Sons,2000:77.
  • 7Petersson JS, Christoffersson JO, Golman K. MRI simulation u-sing the k-space formalism. Magn Reson Imaging, 1993,11(4):557-568.
  • 8Papanikolaou N, Moulopoulos LA, Gouliamos A, et al. Compar-ison of dual spin echo echo planar imaging (SE_EPI) , turbo spinecho with fat suppression and conventional dual spin echo se-quences for T (2 )-weighted MR imaging of focal liver lesions.Magn Reson Imaging, 2000,18(6) : 715-719.
  • 9Pruessmann KP, Weiger M, Scheidegger MB,et al. SENSE:Sensitivity encoding for fast MRI. Magn Reson Med, 1999,42(5):952-962.
  • 10Lustig M,Donoho D, Pauly JM. Sparse MRI: The application ofcompressed sensing for rapid MR imaging. Magn Reson Med,2007,58(6):1182-1195.

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部